ICD-SX700/SX800 4-127-580-11(1)
GB
8
Press
(record/pause) to start
recording.
“
” flashes and the IC recorder
enters the recording pause mode.
9
Start playback on the component
connected to the IC recorder.
“
” appears on the display and
synchronized recording starts.
The synchronized recording pauses
when no sound is detected for more
than 2 seconds, and “
” flashes.
The IC recorder starts recording again as
a new message when sound is detected.
Notes
During synchronized recording, you cannot
divide a recording message (page 43), you
cannot pause recording (page 29), you
cannot record with the VOR function or
you cannot record with the pre-recording
function.
Depending on the equipment connected to
the IC recorder, the synchronized recording
function may not operate properly due to a
difference in the audio input level.
To record without using
the synchronized recording
function
1
Press and hold /MENU to enter
the menu mode.
The menu mode window will be
displayed.
2
Press
or
to select “DETAIL
MENU,” then press
.
3
Press
or
to select “SYNC
REC,” then press
.
4
Press
or
to select “OFF,”
then press
.