50
Instruction for use | Supercal 5
11.2 Power Supplies
The Supercal 5 is always supplied with a battery and can also be supplied with mains power
supply module. These can be modified and retrofitted at any time.
11.2.1 Mains Modules
12- 24 VDC or 12- 36 VAC Article number: SC5X00011
Type
safety extra-low voltage
Voltage tolerance
+10/–15 %
Relative Humidity
93 %
Galvanic isolation
Yes
110- 230 VAC – 50 / 60 Hz. Article number SC5X00012
Type
Protection class II
Frequency
50/60 Hz
Input voltage range
90–260 V
Relative Humidity
93 %
Protection
6A
11.2.2 Battery Modules
Lithium D – Cell Article Number SC5X00010
Nominal voltage
3,6 V
Life
up to 12 +1 year (in combination with
self-sufficient flow sensors)
Maximum ambient temperature
55 °C
Backup battery
type
A (standard ANSI) with connector
Nominal voltage
3,6 VDC
Nominal capacity
min. 4,1 Ah
Maximum ambient temperature
55 °C
11.2.3 Estimating the Battery Life of an M-Bus Application
The battery life of Supercal 5
doesn’t
depend on any of these parameters:
Number of M-Bus devices attached to the M-Bus network
Network specifications, communication speed
Ambient temperature (5 °C–55 °C)
11.3 Measurement concept
The Supercal 5 measurement calculation is based on volume calculation. The number of
electrical pulses determines the volume directly.
Once the volume is determined, the flow rate is calculated according to this volume, and
the time taken for the pulses to occur.
The heat transfer is calculated from flow rate and the difference between “high temper
-
ature” and “low temperature”.
The heat capacity and density of the heat transfer medium are included in the calcula-
tion.