10 Troubleshooting
PROBLEM
Possible Cause
Solution
Pilot will not light
– Gas valve may be OFF
– Tank fuel empty
– Opening blocked
– Air in supply system
– Loose connections
– Turn the gas valve ON
– Refil LPG tank
– Clean opening
– Remove air from lines
– Check all fittings
Pilot will not stay on
– Debris around pilot
– Loose connections
– Thermocouple damaged
– Gas leak in line
– Lack of fuel pressure
– Clean dirty area
– Tighten connections
– Replace thermocouple
– Replace line
– Tank nearly empty. Refill LPG tank
Burner will not light
– Pressure is too low
– Opening blocked
– Control not turned on
– Thermocouple damaged
– Pilot light assembly bent
– Not in correct location
– Tank nearly empty. Refill LPG tank
– Clean the opening
– Turn control to ON
– Replace thermocouple
– Place pilot properly
– Position properly and tetry