3.2 System components 

The sonnenProtect 1300-AU-IN-ATS comprises of an electrical switching arrangement that is installed and 
contained within the main (top) unit of the sonnenBatterie eco 9.43 system.  The power supply from the 
accessory consists of a cable existing from the top of the main unit. This cable will be terminated into the 
protective device of a backup load supply which has to be supplied, installed, connected and tested by the 
installer. The arrangement will supply dedicated circuits / appliances which are to be backed up in the event of 
a power failure to a load required not exceeding 1300W.  

4 Function 

4.1 Basic principle 

The power output of the sonnenProtect supplies electrical power both in grid and emergency operation. The 
storage  system  with  sonnenProtect  accessory  automatically  toggles  between  grid  operation  to  emergency 
operation. The switchover time between grid and emergency operation is stated in the technical data. 

4.2 Grid operation   no grid outage 

If  the  public  electricity  grid  is  not  experiencing  an  outage,  the  backup  load  circuits  connected  to  the 
sonnenProtect backup supply will be continuously supplied with electrical power. This electrical power is drawn 
directly  from  the  grid  and  the  batteries  of  the  storage  system  are  not  discharged  by  the  usage  of  the 
sonnenProtect arrangement.  

4.3 Emergency operation   grid outage 

The  sonnenBatterie  storage  system  automatically  detects  grid  outages  and  disconnects  from  the  public 
electricity grid. The power output from the sonnenProtect arrangement is supplied with electrical power from 
the battery capacity until the backup buffer of the storage system batteries is depleted. Once the backup buffer 

put of the sonnenProtect is no 

longer supplied with electrical power.  
 

1   Total capacity 

2   Available electrical power in grid operation 

3   Backup buffer 

4   Minimum state of charge 

 

The storage system switches back to grid operation with a delay, after a grid outage. This can take a few minutes. 
During this time the output of the sonnenProtect is supplied with power in emergency operation. 

 

Summary of Contents for Protect 1300-AU-IN-ATS

Page 1: ...Operating instructions sonnenProtect 1300 AU IN ATS KD AUD0420 Art Nr 130003 Version X01 support sonnen com au www sonnen com au...

Page 2: ...he product environment 5 2 5 Voltage inside the sonnenProtect accessories 5 3 Product description 6 3 1 Technical data 6 3 2 System components 7 4 Function 7 4 1 Basic principle 7 4 2 Grid operation n...

Page 3: ...the storage system and the sonnenProtect 1 2 Designations in this document The following designations are used in this document complete designation designation in this document sonnenBatterie eco 9...

Page 4: ...f the sonnenProtect must not be connected to the building mains Only connect an electrical consumer that does not exceed the nominal power in continuous operation and maximum power when switched on of...

Page 5: ...otect and the storage system must be wired in accordance with the product documentation The number of plug outputs on the sonnenProtect must not be changed All repairs on the sonnenProtect must be per...

Page 6: ...ed Switchover time approx 15 seconds Safety Minimum Protection Standard IEC 61009 1 AS NZ 61009 1 Required Protective functions Overcurrent Earth Leakage required Degree of protection Specified by ins...

Page 7: ...echnical data 4 2 Grid operation no grid outage If the public electricity grid is not experiencing an outage the backup load circuits connected to the sonnenProtect backup supply will be continuously...

Page 8: ...switched on Do not attempt to switch on the storage system more than three times Contact the sonnen support Australia Further attempts can damage the battery modules Fuse switch F1 establishes the con...

Page 9: ...ecking function Maintenance interval Action to be taken Every 6 months Check the function of the insulation monitor with help of the Test key see 3 2 6 2 Cleaning Risk of material damage due to use of...

Page 10: ...system The RCD and or overall power from the sonnenBatterie is switching off immediately or after the sonnenProtect has been operating for a longer period An electrical consumer with a power consumpti...

Page 11: ...tect Danger to life due to electrocution The sonnenProtect must only be uninstalled by authorized electricians 8 1 2 Disposal The sonnenProtect must not be disposed of as domestic waste Dispose of the...

Page 12: ...12 www sonnen com au www sonnensupport com au...

Reviews: