44
13
Embedded Web Server
AoIP Stream
– This se�ng is the name of the AoIP stream that will be
routed to the selected output, if the output is ac�ve. The stream name is
comprised of the AoIP stream name prefix and the intercom name. For
example, if the required AoIP stream, called “Input1”, is being transmi�ed
from an intercom unit with the name “DEMO-SOURCE”, the AoIP stream
name would be “Input1@DEMO-SOURCE”. This name can be entered
manually, or it can be selected from the dynamic list of available AoIP
streams detailed below. This op�on is unavailable when the source is set to
one of the local audio inputs.
Available AoIP Streams
– This dynamic drop down list shows the AoIP
streams that are currently visible on the network. Selec�ng an AoIP stream
from this list places the name into the AoIP stream edit box. This op�on is
unavailable when the source is set to one of the local audio inputs.
Active
– This op�on routes the selected source to the associated output. If
the output source is set to an AoIP stream and that stream is not currently
available, the output will be muted.
Audio Line Up
– The output audio line up applies to the balanced stereo
line output 2 and the balanced mono input/output. It sets the analogue
audio output level that corresponds to full scale digits when converted from
digital audio. It is recommended to use a similar value on all equipment
that offers variable output line up.
Audio - Output Se�ngs Defaults
Output 1 – 3:
Source:
Input 1
AoIP Stream:
not set
Ac�ve:
Disabled
Audio Line Up:
+18dBu = 0dBFS
Audio - Monitor & Speaker Settings Web Page
The Monitor & Speaker Se�ngs page is located under the Audio sub tab
and it shows the current assignments for the 2 monitor channels. The
loudspeaker op�ons are also set here.
Fig 13-19: Audio - Monitor & Speaker Se�ngs Web Page