![Sonifex AVN-MPPR Handbook Download Page 15](http://html1.mh-extra.com/html/sonifex/avn-mppr/avn-mppr_handbook_1321160015.webp)
7
AVN-MPPR Presenter Remote Unit
3
Front Panel Controls
Status and Mixer ID LEDs
On the left side of the panel, there are a number of status LEDs and above
the word “Mixer” there is also an indication of the virtual mixer being
controlled. When the unit has been grabbed by a mix engine and assigned
to a virtual mixer, the appropriate LED will be illuminated to indicate the
virtual mixer currently under control. If the unit is not currently assigned to
a virtual mixer, the Mixer ID LEDs will all flash red to indicate that this is the
case.
There are also a number of status LEDs which are used to provide a basic
overview of various system parameters. A software enabled limiter on the
Virtual Mixer output is configured to prevent audio over-hitting. When the
limiter is operational, the front panel Limit LED illuminates red. The front
panel also has LED indication to warn of power supply failure, network and
sync/clock failures.
Each of these LEDs can be illuminated in different combinations of colours
and flashing or non-flashing states. The table on the next page provides and
what each LED state signifies.
Led
Name
State
Description
AoIP
Off
Unit has not joined an audio multicast group.
Red
Unit has joined an audio multicast group but no
audio data is being received
Green
Unit has joined an audio multicast group and
audio data is being received.
Ethernet
Red
No network connection
Green
Network connected
Limit
Off
Audio level for the virtual mixer that is under
control is OK
Red
Audio level for the virtual mixer that is under
control is limiting.
Auth
Flash
Yellow
Unit has not yet been grabbed by a mix engine.
Green
Unit has been grabbed by a mix engine
Clock
Red
PTP master offset clock is greater than 10000ns.
Yellow
PTP master offset is less than 10000ns but
greater than 1000ns.
Green
PTP master offset is less than 1000ns. Or this unit
is the master clock.
Flash
Yellow
PTP in listening state – master clock negotiation
taking place.
Power
Red
Power state error
Yellow
Power state warning
Green
Power state is OK