background image

SRA EX9000 System Fan Installation 

Guide

This document provides instructions for removing and installing 

a replacement system fan module on your SonicWall SRA 

EX9000 appliance.

Removing the System Fan from the SRA 

Appliance

To remove an existing or defective system fan from the SRA 

appliance:

1 There is no need to power down the appliance. With a 

Phillips screwdriver, loosen the thumbscrews securing the 

metal vent fan cover.

2 Locate the fan unit that needs to be replaced. Loosen the 

screws with a Phillips screwdriver.

3 Pull the fan module straight out of the appliance, noting its 

orientation, and set it aside.

Inserting the System Fan into the SRA 

Appliance 

To insert the new system fan module into the SRA Appliance, 

perform the following steps:

1 Remove the new system fan module and the SonicWall 

tamper-evident sticker from the replacement fan shipping 

package.

2 Insert the fan module into the empty slot, using the same 

orientation as you noted when you removed the defective 

module.

3 Push the fan module firmly into place to properly seat the 

electronic connectors.

4 Using a Phillips screwdriver, tighten the screws for the fan 

module until it is snug.

5 Confirm that the new fan is operating correctly by verifying 

that the Alarm LED on the front of the appliance is no longer 

lit.

6 Replace the metal vent fan cover, and tighten screws until 

snug.

7 Peel the backing off the silver SonicWall tamper-evident 

sticker, and apply the sticker so 

that it adheres to both the 

vented cover plate and the main chassis of the unit.

A Note Regarding the Tamper-Evident Sticker

The SonicWall silver sticker is a tamper-evident label and is 

required for FIPS compliant mode.
After replacing the system fan, you 

must

 replace the tamper-

evident sticker in order for the unit to maintain its FIPS 

classification.