6-39
6. 10. 4. Range and Depth Change
The display of the scale in the vertical axis direction on the orthogonal screen can be
changed between the range display and the depth display.
< Changing procedure >
(1)
Press the menu key
to open the menu.
(2)
Place the cross cursor over “Screen/Sub Screen,” and press the menu key
to open “Screen/Sub Screen” menu.
(3)
Place the cross cursor
over “Orthogonal”, and press the menu key
to
open the “Orthogonal” menu.
(4)
Place the cross cursor over “Display Axis”, and press the menu key
to
open the “Display Axis” menu.
(5)
Place the cross cursor over the depth item, and press the menu key
to change the distance axis display.
The scale of the vertical axis
shows the range.
The scale of the vertical axis
shows the depth. The scale
changes according to the tilt.
Range display
Depth display