S-36 VLF
– USER MANUAL
27
5.2
Important transport directions
The S-36 VLF should always be handled with great care during transport. Greater mechanical loads
such as shocks or dropping to the ground must be strictly avoided!
WARNING!
The high-voltage device may be transported and stored only in the vertical position.
Non-observance of this requirement may cause leakage of transformer oil from
the safety valve!
Moreover, if the position deviates extremely from the vertical posi-
tion, the
high-voltage winding of the transformer may become irreversibly dam-
aged
.
6
Troubleshooting
If the device does not work properly or cannot be put into operation, carry out the following simple
checks and mind the hints given before sending the device to the manufacturer.
Fault:
No function, signal lamp
„Mains On“ does not illuminate
Has the device been properly connected to the mains, and is mains voltage existing?
Is EMERGENCY STOP button released?
Are fuses properly inserted? Is any fuse defective?
Fault:
Signal lamp „Ground connection“ does not illuminate
Are test object, high-voltage unit and operating unit properly grounded?
Is the high-voltage unit properly connected to operating unit? Is the connector locked?
In case of power supply from inverter or emergency generator set: Has protective ground
been connected to the operating unit?
Fault:
Undefined behaviour of control
To reset the control, switch the unit off with the mains switch
Mains
, and then switch it on
again after about 5 seconds.