PAT-806-IT
– USER MANUAL
29
4.4.1 Two-wire measurement of protective lead resistance using 10/25 A
current
Connect the mains plug of the tested device into the test socket of the me-
ter. Use the probe connected to socket
I2
and touch metal parts of the test-
ed device connected to PE.
The method of measurement and observations are the same as for the measurement of 200mA.
4.4.2 Compensation of the test lead resistance during the measurement of
the protective lead resistance using 10 A or 25 A current (auto-zero)
In
R
PE
10A
or
25A
mode, press
. Auto-zero
screen will appear with blinking symbol
.
Use the probe connected to
I2
socket and touch PE pin of
the test socket.