                SM2130B-C2H2    Us er Ma nual                   

http://www.sonbus.com/ 

Sha nghai Son

best Industrial Co., Ltd                                                                             Page1

 

 

SM2130B-C2H2 

RS485 interface protection type acetylene gas sensor 

User Manual   

 

File Version: V21.3.24

   

        SM2130B-C2H2 using the standard    RS485 bus MODBUS-RTU protocol,easy access to PLC

DCS 

and other instruments or systems for monitoring acetylene state quantities.The internal use of 

high-precision sensing core and related devices to ensure high reliability and excellent long-term 

stability,can be customized RS232,RS485,CAN,4-20mA,DC0~5V\10V,ZIGBEE,Lora,WIFI,GPRS and 

other output methods. 

        Technical Parameters 

Technical parameter 

Parameter value 

Summary of Contents for SM2130B-C2H2

Page 1: ...rd RS485 bus MODBUS RTU protocol easy access to PLC DCS and other instruments or systems for monitoring acetylene state quantities The internal use of high precision sensing core and related devices to ensure high reliability and excellent long term stability can be customized RS232 RS485 CAN 4 20mA DC0 5V 10V ZIGBEE Lora WIFI GPRS and other output methods Technical Parameters Technical parameter ...

Page 2: ...ommands are hexadecimal data The default device address is 1 when the device is shipped the default baud rate is 9600 8 n 1 1 Read Data Function id 0x03 Inquiry frame hexadecimal sending example Query 1 device 1 data the host computer sends the command 01 03 00 00 00 01 84 0A Device ID Function id Start Address Data Length CRC16 01 03 00 00 00 01 84 0A For the correct query frame the device will r...

Page 3: ...ID Function id Start Address Destination CRC16 01 06 00 66 00 02 E8 14 After the change is successful the device will return information 02 06 00 66 00 02 E8 27 its format is parsed as shown in the following table Device ID Function id Start Address Destination CRC16 01 06 00 66 00 02 E8 27 Response should be in the data after the modification is successful the first byte is the new device address...

Page 4: ... example the response data is 01 03 02 00 64 B9 AF the format of which is as shown in the following table Device ID Function id Data Length Data value CRC16 01 03 02 00 64 B9 AF In the response data the first byte 01 indicates the real address of the current device and 00 6B is the first state quantity correction value register If the device has multiple parameters other parameters operate in this...

Page 5: ... ShanghaiSonbest Industrial Co Ltd Page5 Address Building 8 No 215 North east road Baoshan District Shanghai China Web http www sonbest com Web http www sonbus com SKYPE soobuu Email sale sonbest com Tel 86 021 51083595 66862055 66862075 66861077 ...