19. Position the transducer endcap next to the transducer housing.
20. For fitment instructions of the directional transducer endcap, see
Directional Transducer Endcap"
; for fitment instructions of the omni-directional transducer
endcap, see
Section 8.10.2 "Fitment of the Omni-Directional Transducer Endcap"
.
8.12 Corrosion Removal
Cases of slight corrosion found on the transponder housing can be treated effectively as described
below.
1. Ensure the instrument is thoroughly clean and dry.
2. Clean the corroded area with a degreaser.
3. Treat the corroded area with Alocrom for approximately two minutes, or until the aluminium
changes colour to golden brown.
4. Wash off with clean fresh water and dry thoroughly.
5. Ensure the corroded area is completely dry then cover the exposed metal with 2-part epoxy.
Section 8 – Maintenance
58