WSM6 Manual
Document Ref: UM-8270-000
Issue: A Rev 0
Section 7
50
7.4.2
General Status
1. On
the
WSM
Terminal
main screen select the
Get Status
button to populate the screen with
the current configuration of the connected Transponder.
Figure 7-5 – Get Status current configuration
2.
If there is no RS232 communication with the Transponder, check the following:
The WSM6 is switched on
The Serial port settings are correct, refer to
Section 7.4.1.1 – Serial port settings
cable connections are clean and secure.
Check the WSM battery is charged (refer to
Section 6.3 – WSM6 Battery Charging
)
3.
If a successful reply is obtained, all boxes will be populated.
, details all the boxes and their meanings
4.
In the Nav Scheme selection, choose between HPR or Sonardyne.
5.
In the Reply Type selection, choose between Tone and Wideband.
6.
With the Nav Scheme set to Sonardyne, and the Reply Type set to Wideband® 1, the current
Interrogate Channel, command Address and Wideband Individual Reply Signal (IRS) Reply
will be displayed.
October 2011