background image

L

= Mains phase

N

= Mains neutral

C

= common

= UP

= DOWN

KEY SWITCH

Blue

Brown

▼▲

2 x 1,5 mm2

Neutral

Phase

MAINS

230V - 50Hz

Dry contacts TRANSMITTER

N

C

L

▼ ▲

2

1

3

4

The 

DRY CONTACT TRANSMITTER 

is a RTS control that can be controlled driven by a key swit-

ch, a paddle switch, a Centralis IB or a dry contacts rain sensor.
The UP or DOWN radio commands are achieved when the UP or DOWN inputs (

▲ ▼

) are connec-

ted with the common input (

C

). The STOP command is achieved when the three inputs (

▲ ▼ 

C

)

are conected together.

Hereby, SOMFY, declares that this
equipment is in compliance with the
essential requirements and other rele-
vant provisions of Directive 1999/5/EC.
A Declaration of Conformity is available
at the web address 

www.somfy.com

Heading 

CE

L

= Mains phase

N

= Mains neutral

C

= common

= UP

= DOWN

CENTRALIS IB

+

C

Set the switch on 

the "

-

" position

▼▲

+

-

2 x 1,5 mm2

Neutral

Phase

MAINS

230V - 50Hz

Dry contacts TRANSMITTER

-

N

C

L

Blue

Brown

45 mm

usable in EU, CH

• Supply : 220-240V 2,5A 50/60Hz
• Fuse : 3,15A
• Transmission timing :  min0,5 sec.

max10 sec.

• Frequency : 433.42 MHz
• Protection index : IP30
• Temperature : +5°C to +40°C

• Class II product 

80 mm

80 mm

R

PROG

,S,

,S

LED

Programing
button

Built-in manual
security control

C

5 4 3

2 1

SUPPLY

230V 50Hz

Phase

Neutral

Earth

C

5 4 3

2 1

SUPPLY

230V 50Hz

Phase

Neutral

Earth

This device must be installed and programmed by qualified installers for whom this instruction is inten-
ded.

Before connecting the unit, read the instructions carefully.

1

Characteristics

2

Installation

INSTALLATION

guide

Ref

.5006405A

inteo

DRY CONTACT TRANSMITTER

We reserve the right to make changes due to technical improvements. 

DRY CONTACT TRANSMITTER

Cabling of a CENTRALIS IB

Cabling of a Key switch

notice dry contact  10/03/03  16:23  Page 1