background image

 

„

 The same as traditional HID lighting. There are two installation methods, suitable for various 

occasion. 

„

 An internal power-factor-corrected  switch-mode supply allows it to be used from 

any nominal 100-277V&277-480V, 50~60Hz AC supply without any variation in light

 

output. 

„

 Suitable for use in the following locations: 

• 

Ambient Temp: -40~+40°C 

• 

Wet Locations 

Note

: Save these instructions for future reference. 

 

2.

 

Installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For supply connections use wire rated for at least 90

°

C   

Installation Steps: 

 

Refer to the following diagram when you  install the fixture. Seven  installation methods, directly fix to the 

mounting surface or fix to a post with a knuckle. 

1.Directly fix to mounting surface

 

 

Warning: 

To avoid the risk of fire, explosion, or electric shock, this product should be installed, 

inspected, and maintained by a qualified electrician only, in accordance with all applicable 

electrical codes. 

Warning: 

To avoid electric shock: 

Be certain electrical power is OFF before and during installation and maintenance. 

Luminaire must be connected to a wiring system with an equipment-grounding conductor. 

Warning: 

To avoid explosion: 

Make sure the supply voltage is the same as the rated luminaire voltage. 

Do not install where the marked operating temperatures exceed the ignition temperature of 

the hazardous atmosphere. 

Do not operate in ambient temperatures above those indicated on the luminaire nameplate. 

Keep lens tightly closed when in operation. 

TLFLK100PXYYZZ/TLFLK100PHXYYZZ 
TLFLK150PXYYZZ/TLFLK150PHXYYZZ 
TLFLK200XYYZZ 
TLFLK230PXYYZZ/TLFLK230PHXYYZZ 
TLFLK300PXYYZZ/TLFLK300PHXYYZZ 
TLFLK400PXYYZZ/TLFLK400PXYYZZ 

 
 

STL-FLK100PXYYZZ/STL-FLK100PHXYYZZ
STL-FLK150PXYYZZ/STL-FLK150PHXYYZZ
STL-FLK200PXYYZZ
STL-FLK2300PXYYZZ/STL-FLK230PHXYYZZ
STL-FLK300PXYYZZ/STL-FLK300PHXYYZZ
STL-FLK400PXYYZZ/STL-FLK400PHXYYZZ

To avoid the rish of fire, explosion or electric shock, this product should be installed,

inspected, and maintained by a qualified electrician only, in accordance with all applicable

electrical codes.

To avoid electric shock:

- Be certain electrical power is OFF before and during installation and maintanence.

- Luminaire must be connected to a wiring system with an equipment-grounding conductor.

To avoid explosion:

- Make sure the supply voltage is the same as the rated luminaire voltage.

- Do no install where the marked operating temperatures exceed the ignition temperature

of the hazardous atmosphere.

- Do not operate in ambient temperatures above those indicated on the luminaire nameplate.

- Keep lens tightly closed when in operation.

For supply connections use wire rated for at least 90˚C

FOR MORE LIGHTING INFO CALL

1460 PARK AVENUE, EMERYVILLE, CA 94608

510.891.1056

[email protected] 

SOLTECHLIGHTING.COM

2.   Installation