Sollae Systems
https://www.ezTCP.com
4-Port I/O Gateway
SIG-5601 User Manual
Version 1.1
Page 1: ...Sollae Systems https www ezTCP com 4 Port I O Gateway SIG 5601 User Manual Version 1 1...
Page 2: ...cal and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences to the environment and human health which could otherwise be caused...
Page 3: ...igital Input Port 11 1 4 9 USB Host Port 14 2 Preparation 15 2 1 Installing the Setting Tool 15 2 2 Connecting a Product 15 2 3 Searching Devices 15 2 4 Logging in 15 3 Settings 16 3 1 Network 16 3 1...
Page 4: ...l Upgrade 32 4 2 3 Remote Upgrade via cloud 32 4 3 Console 33 4 3 1 Output Tab 33 4 3 2 FW Log Tab 34 4 3 3 Timeout 34 4 4 Export Import Setting Values 35 4 5 Factory Reset 36 5 Technical Support and...
Page 5: ...ports by using a web browser on your PC tablet or smartphone This document presents the information related to device only To connect the device to Sollae Cloud see Sollae Cloud User Guide 1 2 Feature...
Page 6: ...o Sense Wireless LAN IEEE802 11b g Wireless LAN with a USB dongle Software Functions Wireless LAN Mode Infrastructure Protocols IP TCP ICMP DHCP mDNS MQTT SSL TLS 1 2 WPA PSK WPA2 PSK WPA Enterprise T...
Page 7: ...SIG 5601 User Manual Ver 1 1 6 https www ezTCP com KC Registration KN 32 KN 35 CE EMC 2014 30 EU RoHS 2011 65 EU FCC FCC Part 15 Subpart B Class A Table 1 1 Specification...
Page 8: ...ace 1 4 1 Power PWR1 Port This port is one of the main input ports for supplying power DC 8 5V 38V This port is interfaced with a 2 pole terminal block PWR2 Port This port is one of the main input por...
Page 9: ...for making a connection with a PC via USB cable 1 4 4 Function Button This button is used to implement a factory reset 1 4 5 Analog Input Port This port is interfaced with a 5mm pitch 8 pole terminal...
Page 10: ...ning RUN When the script is running RUN When a network is not connected LINK When a network is connected LINK When an IP address is not assigned LINK When a MQTT connection is NOT established STS When...
Page 11: ...nt at DC 30V Normal Open 5A Normal Close 1A Table 1 3 Port Specification The port specifications are for resistive loads For capacitive loads such as SMPS and inductive loads such as motors the curren...
Page 12: ...a 5mm pitch 8 pole terminal block Figure 1 6 Digital Input Port Port Specification Division Value Number of ports 4 Maximum Input Voltage DC 25V Voltage Required for HIGH decision higher than DC 4 5V...
Page 13: ...SIG 5601 User Manual Ver 1 1 12 https www ezTCP com Figure 1 7 Circuit Diagram of Digital Input...
Page 14: ...SIG 5601 User Manual Ver 1 1 13 https www ezTCP com WET contact Figure 1 8 WET contact DRY contact Figure 1 9 DRY contact...
Page 15: ...transistor Figure 1 11 PNP transistor 1 4 9 USB Host Port This port is for connecting a USB wireless LAN adapter You can connect your product to IEEE802 11b g wireless LAN with connecting a USB wirele...
Page 16: ...ia a LAN cable or a USB cable In the case of using a LAN cable note that your PC and the product should be on the same local area network 2 3 Searching Devices Run spFinder on your PC and press the se...
Page 17: ...IP address automatically This product can automatically obtain an IP address by DHCP A DHCP server is required to use this Figure 3 1 Obtain an IP address automatically Select the Obtain an IP address...
Page 18: ...com 3 1 2 Use a Static IP address You can set a static IP address to this product Figure 3 2 Use a static IP address Select the Use static IP address Set the Local IP address Subnet mask Gateway IP a...
Page 19: ...s not suitable for the cloud connected devices 3 2 1 Infrastructure Figure 3 3 Infrastructure mode The wireless network includes an Access Point AP in the infrastructure mode Related information of th...
Page 20: ...SIG 5601 User Manual Ver 1 1 19 https www ezTCP com Click the Save button...
Page 21: ...802 11b and 802 11b g mode Short Preamble Under good condition of WLAN environment you can expect a slight improvement by enabling this option Otherwise you had batter to disable this option Short Slo...
Page 22: ...can be selected among 0 5V 4 20mA and 0 20mA The default value is 0 5V The analog input mode can be set via spFinder only It is impossible to set via Sollae Cloud 3 3 3 Digital Input Valid Time Unit m...
Page 23: ...n and Default Count Value can also be set via Sollae Cloud after the device is registered under an account 3 3 4 Digital Output Fail Safe Mode This item is to enable disable the Fail Safe function Whe...
Page 24: ...ord Click the Save button 3 4 2 Certificate All TLS certificates were preloaded to the device please ignore this part 3 4 3 spFinder These items are related to spFinder use Local search If this item i...
Page 25: ...SIG 5601 User Manual Ver 1 1 24 https www ezTCP com set only when the product is connected via USB...
Page 26: ...ess If this item is checked the product can be connected from the remote network For security this item is unchecked by default 3 4 4 Client ID The Unique ID which is used to register the device under...
Page 27: ...ting the product with spFinder press the Status button to display this window When you open this window the spFinder connects to the product and keeps the connection until you close the window or time...
Page 28: ...me since it boots up day hour min sec IPv4 Assigned IPv4 address Subnet Assigned subnet mask Gateway Assigned gateway IP address DNS Assigned DNS server IP address SSID The SSID of WLAN Table 4 1 Prod...
Page 29: ...TING Connecting SSL CLOSING Closing connection SSL CONNECTED Connected Table 4 3 SSL STATE DEVICE STATE The device operation state Status STARTING UPDATING INFORMATION TO CLOUD FAILED TO UPDATE INFORM...
Page 30: ...9 https www ezTCP com 20mA or 0 to 20mA in 0 5V 4 20mA or 0 20mA input types respectively This value may be rescaled by Sollae Cloud to other measurement e g temperature humidity to be displayed on th...
Page 31: ...input port and counter value 0 LOW 1 HIGH Table 4 7 DIGITAL INPUT 4 1 3 Timeout This is the timeout display function that appears in the upper right of the status window When this time reaches zero t...
Page 32: ...ade it to the latest version Firmware can be upgraded online or manually via spFinder or remotely via Cloud 4 2 1 Online Upgrade If you can access to the Internet by your PC the Firmware can be upgrad...
Page 33: ...ad a Firmware file to your PC Search and connect to your product by spFinder Click Advanced Firmware Change menu Select to Manual upgrade on the Firmware Upgrade window Click Select File button and se...
Page 34: ...l you close the window or time out While the connection is maintained other hosts cannot access the product using the spFinder Figure 4 5 Console 4 3 1 Output Tab This tab displays console messages Cl...
Page 35: ...nction that appears in the upper right of the console window When this time reaches zero the connection between spFinder and the product is lost The initial value is 30 minutes If you move the mouse p...
Page 36: ...ing values menu saves setting values of your product as a file The password is not included in the file The Import setting values menu loads a setting values from a file which is saved by the Export s...
Page 37: ...the password Follow the procedure below by checking the status of RUN LED 1 Press and immediately release the function button 2 Press the function button and keep the state more than 5 seconds 3 Once...
Page 38: ...com en support qna php 5 2 Warranty 5 2 1 Free Repair Services For product failures occurring within 2 years after purchase Sollae Systems provides free repair services or exchange the product However...
Page 39: ...applications provided by Sollae Systems for purposes other than those for which they were designed is prohibited Do not use the product in an extremely cold or hot place or in a place where vibration...
Page 40: ...ars planes trucks boats aircraft helicopters etc In the same way the SIG 5601 is not designed or intended or authorized to test develop or be built into applications where failure could create a dange...
Page 41: ...t de donn es caract re commercial ou de toute autre perte financi re provenant de l utilisation ou de l incapacit pouvoir utiliser le bo tier SIG 5601 m me si Sollae Systems Co Ltd ou un de ses distri...
Page 42: ...fecter la fiabilit cr er des dysfonctionnements et ou la destruction du bo tier SIG 5601 sans que la responsabilit de Sollae Systems Co Ltd et de ses distributeurs ne puissent tre mise en cause ni que...
Page 43: ...G 5601 User Manual Ver 1 1 42 https www ezTCP com 7 Revision History Date Version Description Author 2020 12 02 1 0 1 Created Khanh 2021 09 08 1 1 1 Change condition of digital input volt range Amy Ki...