Sollae CIE-H12A User Manual Download Page 1

 

 

 

   
 

 

 

 

 
 
 
 
 
 

Sollae Systems Co., Ltd. 

https://www.ezTCP.com 

 

1port Remote I/O Controller 
(dry / wet contact support) 

CIE-H12A User Manual

 

Version 1.0 
 

Summary of Contents for CIE-H12A

Page 1: ...Sollae Systems Co Ltd https www ezTCP com 1port Remote I O Controller dry wet contact support CIE H12A User Manual Version 1 0...

Page 2: ...cal and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences to the environment and human health which could otherwise be caused...

Page 3: ...1 1 6 4 Power 11 1 6 5 System LED 12 1 6 6 ISP Switch 12 2 Installation and Test 13 2 1 Installation 13 2 1 1 Setting Network Aera 13 2 2 Test operation 15 2 2 1 Modbus TCP Test 15 2 2 2 HTTP Test wit...

Page 4: ...s 26 5 3 Monitoring and controlling on Web HTTP 27 5 3 1 Changing port number for HTTP 27 5 3 2 Uploading Users Webpage 28 6 System Management 29 6 1 Upgrading Firmware 29 6 1 1 Firmware 29 6 1 2 Proc...

Page 5: ...ion Problem over Modbus TCP 46 9 Related material 47 9 1 Technical Documents 47 9 2 Smart phone application 47 10 Technical Support and Warranty 48 10 1Technical Support 48 10 2Warranty 48 10 2 1 Refu...

Page 6: ...ls the relay outputs HTTP Modbus TCP and Macro mode can be used for these functions CIE H12A has two input ports and one output port One of the input ports is a dry contact type and the other one is w...

Page 7: ...2A User Manual Ver 1 0 6 https www ezTCP com 1 3 Application Examples remote I O device server Figure 1 1 remote I O device server Internet Switch Figure 1 2 internet switch Macro mode Figure 1 3 macr...

Page 8: ...ase TX Auto Sensing Auto MDI MDIX Cable Auto sensing Temperature Operate 0 70 Storage 40 85 Certification CE KC Environment Follows Europe RoHS Directive Table 1 1 H W specification 1 5 2 S W specific...

Page 9: ...nput ports the front view In the front panel the DRY IN 0 port is the dry contact type and the WET IN 1 port is the wet contact type The switch input type Dry contact The first input port is a dry con...

Page 10: ...about the polarity The circuit diagram of the input port is shown in the figure below Figure 1 7 a circuit diagram of the input port The voltage specification of the input port is as follows Over 2 2V...

Page 11: ...ng Value Relay contact 0 OFF open 1 ON short Table 1 4 values of the output port The allowed output ports electrical current of voltage conditions are as in the following Voltage Condition Allowed cur...

Page 12: ...ernet It also provides auto MDI MDIX function that can automatically sense a 1 1 cable or cross over cable Each Ethernet device has its own hardware address MAC address CIE H12A is shipped to the mark...

Page 13: ...a connection on a network blinks transferring or receiving network data Front panel DI Yellow On when input ports signal is ON DO Green On when the output port s signal is ON Table 1 6 status of the s...

Page 14: ...et port to a PC It will be no problem if the Ethernet connection is established through network hubs Figure 2 1 the connection between CIE H12A and a PC 2 1 1 Setting Network Aera This step is for set...

Page 15: ...oper values should be set via ezManager Default values of some major parameters are listed on the table below To do the following simple test keep these values during the test Parameters Values Networ...

Page 16: ...can see the window as shown below Figure 2 3 Modbus TCP test program of the ezManager Search connected CIE H12A with Search All button Select a MAC address of searched product on the search result Ch...

Page 17: ...nput the local port for Modbus TCP of CIE H12A In a local area network and steps can be omitted Try to connect by pressing Connect button Then check if the input LEDs are turned on or off with signal...

Page 18: ...HTTP test Input the IP address of your CIE H12A on the address field Ex 10 1 0 1 Check if the input LEDs are turned on or off with HIGH signal Check if the output LED is turned on or off with clickin...

Page 19: ...ial appearance of ezManager 3 1 1 Configuration via LAN Checklists Make sure of the connection between your PC and CIE H12A via Ethernet If they are in the same network MAC Address search button can b...

Page 20: ...on and has 3 communication modes Configuring parameters is also available in this mode ISP mode This mode is for upgrading firmware and HTML files In addition you can set environmental parameters even...

Page 21: ...atically control the output ports by setting MACRO using some basic formula of Boolean Algebra Users can not control the output ports through HTTP or Modbus TCP WEB HTTP Users can monitor and control...

Page 22: ...ection Active Connection requesting a Modbus TCP connection Multiple Connection The numbers for multiple Modbus TCP connections Control Method of FC XX Control method for the output ports of the slave...

Page 23: ...t Base Address 5 1 3 Modbus TCP Master Mode In this mode CIE H12A operates as a Modbus TCP master As a master CIE H12A transmits its input information to the salve and outputs the slave s input value...

Page 24: ...ignated Depending on the setting of multiple connections up to 8 hosts can be connected The active connection CIE H12A tries to establish a connection to the remote host The IP address or host name an...

Page 25: ...s Address Default HMI Address Di Word Read 03 0 40001 04 30001 Di0 Bit Read 02 0 10001 03 0 40001 0 04 30001 0 Di1 Read 02 1 10002 03 0 40001 1 04 30001 1 Table 5 4 Digital input port address Port Bit...

Page 26: ...esis NOT AND OR Each operator is represented by the following symbols Name Sign Description Parenthesis Since calculations within the parenthesis have the highest priority they will be calculated firs...

Page 27: ...Input Port Equations Description Do0 A i0 i1 Perform bit OR i0 and i1 Do0 B i0 i1 Perform bit AND i0 and i1 Then toggle the result Table 5 7 an example of equation The following is the output values...

Page 28: ...ord User name is not required Leave blank or put a random name Password should be the same with a password which is set through the ezManager 5 3 1 Changing port number for HTTP In case you cannot use...

Page 29: ...by yourself Upgrading HTML files CIE H12A has a default webpage when it is manufactured in the factory For advanced users we have been offering some examples sample web pages based on various technol...

Page 30: ...omepage when a new firmware is released You can find it on our website Entering ISP mode Enter ISP mode to download firmware file to CIE H12A Run a TFTP client and ready to send the F W file Run a TFT...

Page 31: ...TTP 6 2 2 Processes Making Users homepage or Downloading sample files Make your own homepage file or use sample homepage files freely available to download at our web site Entering ISP mode Enter ISP...

Page 32: ...e client program Click the Advanced Menu Change F W HTML button Figure 6 3 running TFTP client Click Advanced Menu Change F W HTML menu to run TFTP client Select the Change HTML radio button Input the...

Page 33: ...Using TELNET Once the TELNET option is activated users can remotely log in to CIE H12A If a password is set users should input the password After that messages from CIE H12A appear as shown in the fig...

Page 34: ...ager You can check multiple states with the following commands command option description usage st net Network Status lsh st net uptime System Uptime lsh st uptime sc OP1 OP2 Session Control lsh sc co...

Page 35: ...e st uptime command shows amount of time since CIE H12A has booted up Figure 6 7 st uptime command sc sc command is used when users close a session OP1 means the name of session and OP2 should be CLOS...

Page 36: ...the status is automatically updated in every second Figure 6 10 status window of ezManager FIRMWARE VERSION The name of model and the version of firmware are displayed here SYSTEM UPTIME Operating ti...

Page 37: ...MAC address is automatically stored in the ARP table This information is held for 1 minute If there is no data communication for 1 minute the information will be removed Notify Ports Change IOTRAP ST...

Page 38: ...amples IP address network mask allowed IP address range 10 1 0 1 255 0 0 0 10 1 0 1 10 255 255 254 10 1 0 1 255 255 255 0 10 1 0 1 10 1 0 254 192 168 1 4 255 255 255 255 192 168 1 4 Table 7 1 examples...

Page 39: ...d create host names on the website of DynDNS before use this All about service usage of an account could be changed according to the policy of DynDNS Homepage of DynDNS http dyn com dns Figure 7 1 set...

Page 40: ...d file We can use it for finding out the reason of your problem Debugging messages are broadcasted to entire network via UDP so it might cause serious network traffic Remember you should turn the opti...

Page 41: ...messages from CIE H12A over the network Auto update to display the latest captured file on the screen of MAC Address Information of a selected message Unavailable To start capturing debugging message...

Page 42: ...MTP protocol When ports you selected are changed status of CIE H12A is sent to the Email address you entered Setting E mail notification option Figure 7 4 Notify Input or Output Port Change Check Noti...

Page 43: ...CIE H12A User Manual Ver 1 0 42 https www ezTCP com Figure 7 5 I O port status notification email...

Page 44: ...orts immediately Although it is allowed to set the values in 1ms it is accurate to 10ms rounded down If the timer for the Delay is already running all the subsequent orders for giving signals to the o...

Page 45: ...e firewall functions so it can cause some trouble to search CIE H12A Close or pause these programs before searching the product Stable supply of the power Check if the power is supplied continually If...

Page 46: ...the access may be denied by their firewall Under this circumstance users should ask the person in charge of their network to release ports which will be used Ex TCP 502 UDP 50005 Operation Mode A TCP...

Page 47: ...lated parameters that Unit ID Input Port Base Address Output Port Base Address Poll Interval and Notify Input change Checking which mode is using In case of MACRO or serialized Modbus TCP you can cont...

Page 48: ...u can find the following technical documents at our website Datasheet Modbus TCP of ezTCP Combinations of I O Controllers Digital Pulse Output IP Change Notification DDNS Modmap Users manual etc 9 2 S...

Page 49: ...customer s request to refund the product within two weeks after purchase Sollae Systems will refund the product 10 2 2 Free Repair Services For product failures occurring within 2 years after purchas...

Page 50: ...d applications provided by Sollae Systems for purposes other than those for which they were designed is prohibited Do not use the product in an extremely cold or hot place or in a place where vibratio...

Page 51: ...n financial losses damage to property personal injury or the death of people or animals If you use the CIE H12A voluntarily or involuntarily for such unauthorized applications you agree to subtract So...

Page 52: ...it voiture camion train avion etc ni en milieu explosif ni dans des enceintes nucl aires ni dans des ascenseurs ni dans des a roports ni dans des enceintes hospitaliers ni pour des applications caract...

Page 53: ...ments lectroniques usag s Le symbole de la poubelle barr pr sent sur le bo tier CIE H12A indique que vous ne pouvez pas vous d barrasser de ce dernier de la m me fa on que vos d chets courants Au cont...

Page 54: ...CIE H12A User Manual Ver 1 0 53 https www ezTCP com 12 History Data Version Comments Author 2019 07 02 1 0 Initial release Amy Kim...

Reviews: