SIG-5600 User Manual Ver. 1.0 

 

- 8 - 

https://www.ezTCP.com

 

 

1.4.6

 

LED 

LED operations according to each state are as follows:  

When the supplied power is stable: PWR 

 

When the supplied power is NOT stable: PWR 

 

When the script is running: RUN 

 

When the script is running: RUN 

 

When a network is not connected: LINK 

 

When a network is connected: LINK 

 

When an IP address is not assigned: LINK 

 

When a TCP connection is NOT established: STS 

 

When a TCP connection is established: STS 

 

When sending data to the TCP: MTX 

 

When receiving data from the TCP: MRX 

 

When the input/output port is OFF: Di0 ~ Di3, Do0 ~ Do3 

 

When the input/output port is ON: Di0 ~ Di3, Do0 ~ Do3

 

 

 

 

Summary of Contents for SIG-5600

Page 1: ...Sollae Systems https www ezTCP com 4 Port I O Gateway SIG 5600 User Manual Version 1 0...

Page 2: ...cal and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences to the environment and human health which could otherwise be caused...

Page 3: ...2 2 Preparation 13 2 1 Installing the Setting Tool 13 2 2 Connecting a Product 13 2 3 Searching Devices 13 2 4 Logging in 13 3 Settings 14 3 1 Network 14 3 1 1 Obtain an IP address automatically 14 3...

Page 4: ...aximum Analog Input Value Register 32 5 1 4 Digital Input Status Register 33 5 1 5 Inverted Digital Input Status Register 33 5 1 6 Digital Input Counter Register 33 5 1 7 Device Information Register 3...

Page 5: ...NC output Selectable input mode voltage or current Modbus TCP Support multiple TCP connection Max 4 channels Free Modbus TCP program Industrial temperature range 40 85 1 3 Specification Digital Input...

Page 6: ...Security Password Dimension Size 180mm x 110mm x 26mm Weight about 485g Operating Environment Input Voltage PWR1 Terminal Block DC8 5V 38V PWR2 DC jack DC5V 0 2V USB Setup micro USB DC5V 0 2V Protect...

Page 7: ...ace 1 4 1 Power PWR1 Port This port is one of the main input ports for supplying power DC 8 5V 38V This port is interfaced with a 2 pole terminal block PWR2 Port This port is one of the main input por...

Page 8: ...for making a connection with a PC via USB cable 1 4 4 Function Button This button is used to implement a factory reset 1 4 5 Analog Input Port This port is interfaced with a 5mm pitch 8 pole terminal...

Page 9: ...is running RUN When the script is running RUN When a network is not connected LINK When a network is connected LINK When an IP address is not assigned LINK When a TCP connection is NOT established STS...

Page 10: ...rent at DC 30V Normal Open 5A Normal Close 1A Table 1 3 Port Specification The port specifications are for resistive loads It is recommended to design with a margin of about 10 20 of the maximum allow...

Page 11: ...erminal block Figure 1 6 Digital Input Port Port Specification Division Value Number of ports 4 Maximum Input Voltage DC 25V Voltage Required for ON decision higher than DC 2 5V Voltage for OFF decisi...

Page 12: ...SIG 5600 User Manual Ver 1 0 11 https www ezTCP com WET contact Figure 1 8 WET contact DRY contact Figure 1 9 DRY contact...

Page 13: ...transistor Figure 1 11 PNP transistor 1 4 9 USB Host Port This port is for connecting a USB wireless LAN adapter You can connect your product to IEEE802 11b g wireless LAN with connecting a USB wirele...

Page 14: ...LAN cable or a USB cable In the case of using a LAN cable note that your PC and the product should be on the same local area network 2 3 Searching Devices Run spFinder on your PC and press the search...

Page 15: ...IP address automatically This product can automatically obtain an IP address by DHCP A DHCP server is required to use this Figure 3 1 Obtain an IP address automatically Select the Obtain an IP address...

Page 16: ...com 3 1 2 Use a Static IP address You can set a static IP address to this product Figure 3 2 Use a static IP address Select the Use static IP address Set the Local IP address Subnet mask Gateway IP a...

Page 17: ...gure 3 3 Infrastructure mode The wireless network includes an Access Point AP in the infrastructure mode Related information of the AP SSID shared key and etc is required to be set on your product to...

Page 18: ...to an IP address among 192 168 0 3 to 192 168 255 254 Each client is not allowed to communicate with another client but communicates with SIG 5600 Use this mode when there is no AP on the network or...

Page 19: ...802 11b and 802 11b g mode Short Preamble Under good condition of WLAN environment you can expect a slight improvement by enabling this option Otherwise you had batter to disable this option Short Slo...

Page 20: ...is valid only when the Communication Mode is set to TCP Client Port This item is to set the port number for the TCP connection It can be set between 0 and 65535 The default is 502 Multiple Connection...

Page 21: ...In order for the input signal to be judged as a valid signal it must last longer than the time set in this item The setting unit is milliseconds The range is 100 to 30000 The default value is 100 Noti...

Page 22: ...ting unit is milliseconds The range is 100 to 30 000 and the default value is 1 000 Pulse Interval Unit ms This item is to set the time interval between two pulse signals when the Number is set to a v...

Page 23: ...ick the Save button 3 4 2 Certificate This is NOT available for this product 3 4 3 spFinder These items are related to spFinder use Local search If this item is not checked you will not be able to sea...

Page 24: ...er 1 0 23 https www ezTCP com Remote access If this item is checked the product can be connected from the remote network For security this item is unchecked by default 3 4 4 Client ID This is NOT avai...

Page 25: ...ting the product with spFinder press the Status button to display this window When you open this window the spFinder connects to the product and keeps the connection until you close the window or time...

Page 26: ...me since it boots up day hour min sec IPv4 Assigned IPv4 address Subnet Assigned subnet mask Gateway Assigned gateway IP address DNS Assigned DNS server IP address SSID The SSID of WLAN Table 4 1 Prod...

Page 27: ...able 4 3 MODBUS STATISTICS DEVICE STATISTICS Item Description TCP0 3 The byte count of TCP data TX RX DROP TX The byte count of outgoing TCP data RX The byte count of incoming TCP data DROP The byte c...

Page 28: ...ou can upgrade it to the latest version Firmware can be upgraded online or manually via spFinder 4 2 1 Online Upgrade If you can access to the Internet by your PC the Firmware can be upgraded online F...

Page 29: ...4 4 Manual Upgrade Download a Firmware file to your PC Search and connect to your product by spFinder Click Advanced Firmware Change menu Select to Manual upgrade on the Firmware Upgrade window Click...

Page 30: ...until you close the window or time out While the connection is maintained other hosts cannot access the product using the spFinder Figure 4 5 Console 4 3 1 Output Tab This tab displays console messag...

Page 31: ...n the upper right of the console window When this time reaches zero the connection between spFinder and the product is lost The initial value is 30 minutes If you move the mouse pointer in the interna...

Page 32: ...the password Follow the procedure below by checking the status of RUN LED 1 Press and immediately release the function button 2 Press the function button and keep the state more than 5 seconds 3 Once...

Page 33: ...range of values is 0 to 4905 Division Address Word Count Type Function Code HMI Addressing Example Port 0 16 1 Integer 04 30017 Port 1 17 1 Integer 04 30018 Port 2 18 1 Integer 04 30019 Port 3 19 1 I...

Page 34: ...lues is 0 to 4905 Division Address Bit Count Type Function Code HMI Addressing Example Port 0 80 1 Boolean 02 10081 Port 1 81 1 Boolean 02 10082 Port 2 82 1 Boolean 02 10083 Port 3 83 1 Boolean 02 100...

Page 35: ...ss 442 6 ASCII 03 40443 IP Address 448 8 ASCII 03 40449 Table 5 7 Device Information Register Vendor Name This is the Vendor Name Product Code This is the product code Version Major Minor Revision Thi...

Page 36: ...pulse output ends the corresponding bit is automatically set to 0 This register is allowed to write only when the output mode of the corresponding port is Pulse and cannot be set to 0 Division Address...

Page 37: ...sponding to each port is stored as 1 the minimum and maximum values of the port are initialized and the bit is set to 0 again Division Address Bit Count Type Function Code HMI Addressing Example Port...

Page 38: ...com en support qna php 6 2 Warranty 6 2 1 Free Repair Services For product failures occurring within 2 years after purchase Sollae Systems provides free repair services or exchange the product However...

Page 39: ...applications provided by Sollae Systems for purposes other than those for which they were designed is prohibited Do not use the product in an extremely cold or hot place or in a place where vibration...

Page 40: ...ars planes trucks boats aircraft helicopters etc In the same way the SIG 5600 is not designed or intended or authorized to test develop or be built into applications where failure could create a dange...

Page 41: ...r utiliser le bo tier SIG 5600 m me si Sollae Systems Co Ltd ou un de ses distributeurs a t inform de la possibilit de tels dommages Le bo tier SIG 5600 est exclusivement pr vu pour un usage en int ri...

Page 42: ...llae Systems Co Ltd et de ses distributeurs ne puissent tre mise en cause ni que le bo tier SIG 5600 puisse tre chang au titre de la garantie Rappel sur l vacuation des quipements lectroniques usag s...

Page 43: ...SIG 5600 User Manual Ver 1 0 42 https www ezTCP com 8 Revision History Date Version Description Author 2020 09 08 1 0 1 Created Roy Lee...