
CSE-H25 User
’
s Manual Ver. 1.2
Sollae Systems Co., Ltd.
- 24 -
http://www.sollae.co.kr
4.3
Checking current status
4.3.1 Telnet login
You can log in the CSE-H25 if you enable the [Telnet option] in the [OPTION] tab of the
ezManager. Then you can check the network and serial status after logging in the CSE-
H25. If you press “telnet [CSE-H25‟s IP address]” on the command prompt of Windows,
you can log in CSE-H25
Figure 4-2 Telnet Login
4.3.2 Commands
Network Status
User can monitor network status of CSE-H25 with the “st net” command.
Figure 4-3 Checking Network Status
Serial Ports‟ Status
User can monitor the statuses of two serial ports with the “st sio” command. The
tx_count and the rx_count are the total data sizes to/from the serial ports.
Figure 4-4 Checking Status of RS232 Port
Checking Uptime
With “st uptime” command, you can check the time of your device boots up.