4  Aquavent SDI-12 Operation

Once the AquaVent system has been installed and powered up, you can start 

issuing SDI-12 commands to it. It is good practice to do the following:

4.1 The SDI-12 Address

The factory default address for an AquaVent is “0”. This address identifies 

the AquaVent on an SDI-12 network. The SDI-12 protocol of the AquaVent 

translator has been restricted so that it CANNOT be used to change the 

device address. Since the SDI-12 ‘A’ command is unsupported, the SDI-12 

device address may only be changed by using Solinst Levelogger PC Software  

(see Section 3.1).

4.2 Activation and Verification

1)  Check the SDI-12 device Address of the AquaVent on your SDI-12 network. 

The default is set to address ASCII ‘0’. If the Wellhead LED flashes Yellow in 

response to the appropriately addressed SDI-12 command, this confirms the 

AquaVent address. 

2)  Using your SDI-12 master and its software, issue an Acknowledge Active 

Command ‘a!’, to test if the device address is correct and you can communicate 

with the newly installed Wellhead and AquaVent logger. Make sure other 

SDI-12 devices are not being addressed and communicating at the same time 

on the SDI-12 network.

3)  Issue the Start Verification Command ‘aV!’ and later read it with the Send 

Data Command ‘aD0!’ to verify the Wellhead and AquaVent logger are 

operating without errors.

4)  Use the Send Identification Command ‘aI!’ to verify that the name and model 

of the AquaVent matches that of the AquaVent you have just installed. This 

information was read out of the AquaVent with the last ‘V’ command, or the 

last SDI-12 interface bring-up.

5) Execute the Start Concurrent Measurement Command ‘aC!’ and later 

retrieve the measurement with the Send Data Command ‘aD0!’, to ensure 

the AquaVent is connected properly and taking measurements .

6)  If the above steps are successful, you may program the SDI-12 master to 

automatically issue commands to the AquaVent to take measurements and 

record them.

7) For best operation, do not set the AquaVent to log internally so all 

measurements are controlled and initiated by the SDI-12 master. However, 

you may choose to program your AquaVent to record internally as a back-up. 

See Section 2.

 

  NOTE 

For explanations of the SDI-12 
Supported Commands used to 
communicate with the AquaVent, 
see Section 5.

 

  NOTE 

In all the following SDI-12 
commands discussed, 

a

 = the 

SDI-12 device address assigned the 
AquaVent,

 

  NOTE 

The first yellow flash after the 
SDI-12 interface comes online also 
implies that the Wellhead now 
knows what interface is being used, 
at which time it shuts off unused 
interfaces in order to reduce the 
idle current from several mA to 
several 10’s of uA.

Summary of Contents for AquaVent SDI-12

Page 1: ...SDI 12 User Guide AquaVent July 1 2020 More Info Instructions Get Quote ...

Page 2: ......

Page 3: ...ctivation and Verification 11 4 4 Changing SPX Wellhead Batteries 12 4 5 AquaVent Firmware Upgrades 12 5 SDI 12 Supported Commands 13 5 1 Acknowledge Active Command a 13 5 2 Address Query Command 13 5 3 Send Identification Command aI 13 5 4 Change Address Command aAb 14 5 5 Start Measurement Command aM 14 5 6 Start Measurement Command with Checksum aMC 14 5 7 Send Data Command aD0 14 5 8 Start Con...

Page 4: ......

Page 5: ...are colour coded according to Table 1 1 The bottom of the Wellhead connects to an AquaVent logger through a Vented Cable The AquaVent logger contains a small battery used only for memory and clock back up The Wellhead contains four user replaceable 1 5 V AA lithium batteries that power the AquaVent logger The SDI 12 interface circuitry requires the 12V connection to be powered by customer equipmen...

Page 6: ...interface is online Alternating Yellow Red for 10 rapid cycles would instead mean that communication was NOT established so the SDI 12 interface has been brought online using the default device address of ASCII 0 Check the batteries and the AquaVent logger connections Technical Specifications Standard Compliance SDI 12 Protocol Version 1 3 July 18 2005 except A command Maximum Sample Rate 1 SDI 12...

Page 7: ... will also be using the batteries if programmed to record independently draining the batteries more quickly 2 1 Data Downloading and Programming in Field If the AquaVent logger has been programmed to record on its own independent schedule data can be downloaded from the AquaVent using a laptop and USB Connector Cable in the field see Figure 3 1 Temporarily disconnect the AquaVent from the SDI 12 C...

Page 8: ...address of 0 To set the device address for the AquaVent logger it must be connected to the Levelogger PC Software The AquaVent communicates with the Software using a USB Connector Cable connected to the SPX Wellhead The USB Connector Cable connects to the 10 pin Solinst Protocol connector on the Wellhead NOTE For information on downloading and starting the Levelogger PC Software see the Vented Dat...

Page 9: ...address can be customized to any value from 0 to 9 A to Z or a to z giving a total of 62 unique addresses You can also change the units that the AquaVent will be measuring in for the Level and Temperature Channels Once you have set the address and any other desired settings click the start button This applies the address and settings to the datalogger AND starts the AquaVent logging internally If ...

Page 10: ... the AquaVent with Levelogger Software 5 Turn on power to the SDI 12 master and or the SDI 12 network such that power is applied to the SDI 12 Connector Cable The SPX Wellhead LED should emit the following signals in order Tricolour spin 3 cycles to indicate a power on event Alternating Yellow Green for 10 rapid cycles indicate that AquaVent communication has been established the SDI 12 device add...

Page 11: ...Command aV and later read it with the Send Data Command aD0 to verify the Wellhead and AquaVent logger are operating without errors 4 Use the Send Identification Command aI to verify that the name and model of the AquaVent matches that of the AquaVent you have just installed This information was read out of the AquaVent with the last V command or the last SDI 12 interface bring up 5 Execute the St...

Page 12: ...ttery indicator See the Vented Dataloggers User Guide for instructions to do this Power cycle the Wellhead by temporarily 30 seconds unplugging the SDI 12 Connector Cable This will cause the Wellhead to re connect with the AquaVent Wait for the LED to indicate a good connection Try re connecting if the first try fails 4 5 AquaVent Firmware Upgrades See the Vented Dataloggers User Guide for details...

Page 13: ...command is good for determining the AquaVent address if it is the only datalogger connected on the SDI 12 network 5 3 Send Identification Command aI AquaVent 5 Wellhead This command is used to query AquaVent Loggers for their SDI 12 compatibility level model number and firmware version number A typical command reply would be 0I 013SOLINST M20 V1 1 000 1017687 CR LF where the first 0 is the AquaVen...

Page 14: ...inst AquaVent this is currently two data items temperature and level measurements A typical command reply is 0D0 0 24 2981 0 35212 CR LF where the temperature is the 24 2981 in degrees Celsius and the level is the 0 35212 in meters It is possible to change level units using Levelogger Software but the actual units in use are not reported while the AquaVent is in SDI 12 mode In response to a checks...

Page 15: ...take about 13 seconds A typical session would appear as follows 0V 00131 CR LF indicates that one status reading will be ready in about 13 seconds 0 CR LF is a service request from the SPX Wellhead within 13 seconds to indicate that the BIT operations are complete and the verification code is available 0D0 0 000 is the Send Data command from the SDI 12 master device to obtain the BIT verification ...

Page 16: ...a bus collisions and scrambled data will be returned on replies to the recorder or SDI 12 master This is indicated if two SPX Wellhead yellow LEDs are flashing at the same time when only one SDI 12 command has been sent Change the device address of the AquaVent logger with the duplicate address Also ensure that you only have the SDI 12 Connector Cable connected to the Wellhead It will not work if ...

Page 17: ...ide for AquaVent Page 17 7 References SDI 12 Support Group Technical Committee SDI 12 A Serial Digital Interface Standard for Microprocessor Based Sensors Version 1 3 July 18 2005 Available online http www sdi 12 org ...

Page 18: ...t Canada Ltd 35 Todd Road Georgetown ON L7G 4R8 Tel 1 905 873 2255 800 661 2023 Fax 1 905 873 1992 instruments solinst com www solinst com High Quality Groundwater and Surface Water Monitoring Instrumentation ...

Reviews: