METEOROLOGICAL STATION Solight TE81BK
Operating Instructions
Dear customer, thank you for purchasing our product. If you want it to serve you safely and fully, please read these instructions carefully and follow them. This
will avoid misuse or damage. Avoid unauthorized use of this appliance and always respect all rules regarding the handling of electrical appliances. Keep the
operating instructions for future reference. The main unit should stand as close to a window as possible.
TECHNICAL DATA
We recommend using alkaline batteries with a nominal voltage of 1.5V for proper
LCD display brightness. NiMH rechargeable batteries are usually 1.2V and the LCD
brightness is therefore inferior.
Main unit
If
battery powered
, open the battery cover and insert two AA alkaline batteries
(not included)
. Observe the marked polarity. On start-up, all segments of the
LCD display will momentarily light up and the instrument will beep. It will then enter standard temperature and humidity measurement mode.
If
powered by an AC/DC adapter
, plug the power connector into the input socket on the weather station and then plug into an electrical outlet.
To reset the device, remove the batteries or unplug the adapter for at least five seconds. This will erase all settings and memory. In the case of battery power,
the display will light up for eight seconds each time. If powered by an adapter, it will light continuously.
You can pair the main unit with up to three sensors. Each sensor is powered by two AA alkaline batteries (not included).
Default settings
: 24-hour time format shows 00:00, pressure in mb/hPa and temperature in °C.
1.
BUTTON FUNCTIONS
Room temperature
measurement
0°C to +50°C
Room humidity measurement
20% to 95%
Outdoor temperature
measurement
-40°C to +60°C
Measuring outdoor humidity
20% to 95%
Power
2x AA 1.5V alkaline batteries
AC/DC adapter 5V/1200mA
Temperature measurement
accuracy
1°C
Moisture measurement
accuracy
5%
Atmospheric pressure
measurement range
600 hPa/mb - 1100hPa/mb
Function Control
MEM
on/off
/ Z
Z
Standard
mode
Short
press
Display
date/sec.
Wake-up
time/date
display
Switching °C/°F
Switching
between sensors
/cyclical sensor
display mode
Turns the
temperatu
re alarm
on/off
Changing the
backlight
intensity
displays
Display of
max. and
min.
memory
temperatu
re and
humidity
Switchin
g on/off
alarm
clock
Switching
on the
display
backlight
/suspendi
ng the
wake-up
call
HOLD
Enter time
setting
mode.
Enter
alarm
setting
mode
Activating the
RCC reception
mode
Activation of
signal reception
from sensors
Enter
temperatu
re alarm
setting
mode
Enter change
mode:
pressure/weathe
r units
Deleting
max. and
min.
temperatu
re and
humidity
data
-----
-----
Time
settings
Short
press
Confirm
settings
-----
One step
forward
Back one step
-----
-----
-----
-----
-----
HOLD
-----
-----
Fast forward
Accelerated
posud back
-----
-----
-----
-----
-----
Setting the
alarm
Short
press
-----
-----
One step
forward
Back one step
-----
-----
-----
-----
-----
HOLD
-----
-----
Fast forward
Accelerated
rewind
-----
-----
-----
-----
-----
Setting the
temperatur
e alarm
Short
press
-----
-----
One step
forward
Back one step
Switching
between
max. and
min.
temperatu
re settings
-----
-----
-----
-----
HOLD
-----
-----
Fast forward
Accelerated
rewind
-----
-----
-----
-----
-----