 Solight TE76 METEOROLOGICAL STATION 

 
Instructions for use 
Instructions for use 
Dear customer, thank you for buying our product. If you would like to use it safely and get the most out of it then please read through these instructions carefully 
and follow  them.  That  way  you will  avoid incorrect  use  or  damage.  Prevent  unauthorised  use  of  this  device  and always respect  all  rules related  to  handling 
electronic devices. Keep the instructions for use in case you need them later. The main unit should stand as close to a window as possible.

 

 
TECHNICAL INFORMATION  

 
 

Main unit 
In the case of charging using batteries open the battery cover and insert three AAA alkaline batteries. Observe the marked polarities. When switching on all 
segments the LCD display will light up for a moment and the device will beep. Then it will go into standard mode of measuring temperature and humidity.  
 
In the case of charging using a AC/DC adapter connect the charging connector to the input socket at the meteorological station and then connect to an electrical 
socket.  
 
Reset the equipment by removing the batteries or disconnecting the adapter for at least five seconds. That will return the settings to their defaults and will delete 
the memory. In the case of charging using batteries the display lights up and stays lit for eight seconds each time. In the case of charging using an adapter it is lit 
constantly.  
 
You can only pair up the main unit with three sensors. Each sensor is charged by two AAA alkaline batteries. 
 
Initial settings: 
24-hour time format shows 00:00, pressure is in hPa units, and temperature is in °C 
 
1. FUNCTIONS OF BUTTONS 

 

2. MAIN FUNCTIONS 

 

Date and time (days of the week in seven languages – English, German, French, Italian, Dutch, Spanish and Danish 

 

12-hour or 24-hour time format 

 

Two alarms 

 

Alarm with SNOOZE function (interval adjustable from 3 to 20 minutes, default setting 5 minutes) 

 

RCC signal reception mode: DCC 

 

Measurement of temperature in °C or °F 

 

Measurement of room temperature – range from 0°C - +50°C, accuracy of measu/- 1°C, scope of display (0°C to +50°C) 

Room temperature 
measurement 

0°C to +50° 

Room humidity measurement 

25% to 95% 

Outdoor temperature 
measurement 

-30°C to +60°C 

Outdoor humidity measurement 

25% to 95% 

Power supply 

3x AAA 1.5V alkaline battery 
AC/DC adapter 5V/1,200mA 

Temperature measurement 
accuracy 

1°C 

Humidity measurement 
accuracy 

5% 

                          Function 
Control
 

MODE 

ALARM 

ALERTS 

UP 

DOWN 

CHANNEL 

SNOOZE/LIGHT 

Standard 

mode 

Short 
press 

 

Switch between display 

of time and alarms (AL) 

Switch alarm on and off 

Switch between 

max/min 

Switch 

between 

°C/°F 

Switch 

between 

12h/24h 

Switch between 

CH 1, 2, 3 

Switch between 

under-lighting 

modes 

Long 

press 

Enter into time and 

date setup mode 

Delete information about 

maximum/minimum 

temperature/humidity 

Enter into 

temperature 

alarm setup 

function 

Switch 

barometer 

HPa/inHg 

Activate RCC 

signal 

reception 

Pair transmitter 

with receiver on 

current channel 

Enter into snooze 

setup mode 

Time setting 

Short 
press 

Switch/Confirm setting 

----- 

----- 

One step 
forwards 

One step 

back 

----- 

----- 

Long 

press 

----- 

----- 

----- 

Forwards at a 

speed of 8 

steps per 

second 

Back at a 

speed of 8 

steps per 

second 

 

----- 

----- 

Alarm setting 

Short 
press 

Switch/confirm setting 

----- 

----- 

One step 
forwards 

One step 

back 

----- 

----- 

Long 

press 

----- 

----- 

----- 

Forwards at a 

speed of 8 

steps per 

second 

Back at a 

speed of 8 

steps per 

second 

----- 

----- 

Set up 

temperature 

alarm 

Short 
press 

 

----- 

----- 

Switch/confirm 

setting 

Switch 

temperature 

alarm on and 

off 

Switch 

temperature 

alarm on 

and off 

----- 

----- 

Long 

press 

----- 

----- 

----- 

One step 
forwards 

One step 

back 

----- 

----- 

We recommend using alkaline batteries with a rated voltage of 1.5V for 
the LCD display to be the correct luminescence. Rechargeable NiMH 
batteries usually have a 1.2V rated voltage and the luminescence of the 
LCD display is therefore worse. 