EN
Instructions for Solight 1T04A Breath Analyzer
Thank you for purchasing our digital breath analyzer, which measures the alcohol content of your breath and indicates the possible
level of intoxication.
Description
Power
Batteries
: use only 1.5 V alkaline batteries - 3x AAA LR03. 1.2 V rechargeable batteries are insufficient for the operation of the
device. In particular, when using partially discharged rechargeable batteries, the display intensity may be reduced and the device
will interpret this condition as low batteries.
Open the battery cover by pushing the lock, see arrow in the
picture. Then insert the batteries. Observe the marked polarity.
USB cable:
The cable is not used to charge the batteries, but to
power the device directly. There is no risk of damaging the batteries. You can use any 5V USB power adapter. The output current
does not matter.
Operation
After inserting the batteries or plugging in the USB power cable, the sensor cleaning and warming up process starts automatically.
During this process, the Clr symbol is displayed. The whole process takes about 1 minute. You can skip the process by pressing the
power button twice.
Measurements
1.
Rinse your mouth with clean water before using the breath analyzer. Do not smoke or drink alcohol for at least 10 minutes
prior to the measurement. Taking measurements immediately or shortly after consuming alcohol is inaccurate and usually
also causes damage to the measuring sensor. A claim for this reason would be unjustified.
2.
Tilt the swivel mouthpiece perpendicular to the instrument. Only this swivel mouthpiece can be used for testing. When
testing more than one person, for hygiene reasons, attach the tube (supplied with the device) to the mouthpiece. Use a new
mouthpiece tube for each person.
3.
Press the button for 1 second to switch on the instrument, followed by the activation of the test sensor lasting approximately
40 seconds. The display will start counting down to the number "40", after which "WAIT" will appear and count down to
zero. At the end of the countdown, an audible signal sounds and the text "READY" appears briefly on the display. The display
then flashes "BLOW", indicating that the user can start the test.
4.
At this point, insert the mouthpiece into your mouth and blow continuously for about 5 to 6 seconds. The "BLOW" light will
be on steadily while you are blowing. If blowing is not detected during the "READY" mode, the instrument will display "Err"
and a red backlight.
5.
Stop blowing after the double beep. The device will now start the analysis, which is indicated by flashing the text "READING"
on the display.
6.
The display will show the measured value, e.g
. 0.203 ‰BAC
- i
f the measured value is below 0.200 ‰, the display will show 0.000 ‰ or 0.100 ‰ breath alcohol
- i
f the device measures a value between 0.200 ‰ and 3.000 ‰ breath alcohol, the display will show the measured value
- a preset value of 0.20
0 ‰ will alert you if you exceed the tolerance limit for driving by activating the background display
- when the value of 3.
000 ‰ breath alcohol is exceeded, the texts "3.000" and "NO DRIVING" will flash on the display.
7.
To take a new measurement, press the power button again.
Display
Turn on
Mouthpiece
USB port
Memory
Units
Wait
Ready
Blow
Battery
indicator
No driving
Alcohol content
above the warning
level