SOLiD RocketWAVE™ SRF-L-8A1821 Product Manual
V1.7 - DEC 2021
© 2021 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary.
Page 5
Regulatory Compliance / Certifications for repeater
CE
CE Radio Equipment Directive (RED) Directive
(2014/53/EU)
RF:
ETSI EN 301 908-15 V15.1.1
ETSI EN 301 908-1 V13.1.1 (2019-11)
EN50385:2017
EMC:
ETSI EN 301-489-1 V2.2.3
ETSI EN 301 489-50 V2.3.1
Safety:
EN IEC 62368-1 :2020+A11 :2020
RoHS
2011/65/EU Amended to 2015/863/EU
REACH
EC 1907/2006 REACH Regulation
Regulatory Compliance / Certifications for power supply
CE: EN60950-1 / 62368-1
Electrostatic Discharge Immunity:
IEC61000-4-2:2008
Radiation Electromagnetic Immunity
IEC61000=4-3:2006+A1:2007+A2:2010
FAST TRANSIENT IMMUNITY
IEC61000-4-4:2004
SURGE IMMUNITY
IEC61000-4-5:2005
CONDUCTED DISTURBANCES IMMUNITY
IEC61000-4-6:2008
VOLTAGE DIPS, INTERRUPTION & VARIATIONS
IEC61000-4-11:2004
The installation to comply with European EN50385 exposure compliance requirements, the following
Power Density limits/guidelines (mW/cm
2
) according to ICNIRP are valid:
-
0.2 for frequencies from 10 MHz to 400 MHz
-
F (MHz) / 2000 for frequencies from 400 MHz to 2 GHz
-
1 for frequencies from 2 GHz to 300 GHz
The power supply of the unit complies with Overvoltage Category II. It also complies with the surge re-
quirement according to EN 61000-4-5 (fine protection); however, installation of an additional medium
(via local supply connection) and/or coarse protection (external surge protection) is recommended de-
pending on the individual application in order to avoid damage caused by overcurrent.