background image

 

 

 

 

 

 
 

 

 

 

 

 

 

 

Installation Guide 

Part no. 82BL5G01N 

 

 

 

 

 

 

 

Summary of Contents for L200

Page 1: ...Installation Guide Part no 82BL5G01N ...

Page 2: ...onsole Weight Power Dimensions 11 L200 Console Includes L200 Plus Model 12 L200 Connections Front 12 L200 Console Connections Rear 12 L200 Console Weight Power Dimensions 13 L350 Console Includes L350 Plus Model 14 L350 Connections Front 14 L350 Connections Rear 14 L350 Console Weight Power Dimensions 15 L450 Console 16 L450 Connections Front 16 L450 Console Connections Rear 16 L450 Console Weight...

Page 3: ...idge 29 BLII Bridge Weight Dimensions 29 Net I O X Light Bridge 30 X Light Bridge Weight Dimensions 30 Connections Key 31 Environmental Applicable to all console models 38 Typical Installation Diagrams 38 Simple Single System 38 Blacklight II Single System with Redundancy 39 Dual Console MADI System 40 Dual Console System with Blacklight from each console 41 Optional Console Stand 42 L550 Models S...

Page 4: ...ation requires it If there is a specific requirement for external clocking of a Live system the external clock must match the sample rate at which the Live console is running or PAL 25 NTSC 29 97 video sync Note It is also important that if an external clock is used only the Live console should be connected to the clock source SSL Live stageboxes will receive their clock via the MADI stream from t...

Page 5: ...more information on the Dante Clock Election process please see the Audinate website dev audinate com GA dante controller userguide webhelp clock_synchronization htm To choose a Leader Clock manually set this device to be the Preferred Leader To do this open Dante Controller and click on the Clock Status tab Check the Preferred Leader checkbox for your chosen Leader Clock If multiple devices on th...

Page 6: ...uration is not used as it does not offer network clock redundancy Clocking over a BLII X Light Bridge As detailed in the previous section SSL recommends that the console is set to clock from the Dante network follower mode to benefit from the Dante clock election process This should be done using the local Dante Expander port as described above even if using a BLII X Light Bridge Provided both the...

Page 7: ...lock rates are currently supported Note If running at 96 kHz sample rate 48 x2 the ID field must be set to 1 32 The controls will return to their locked state after a few seconds Daisy Chaining MADI Stageboxes Stageboxes running at 48 kHz sample rate can be daisy chained on a single MADI stream allowing all 64 channels of the MADI protocol to be utilised With the controls unlocked use the ID butto...

Page 8: ...ponding Input AES Pair 44 1 kHz 96 kHz 44 1 kHz 88 2 kHz 176 4 kHz 88 2 kHz 48 kHz 96 kHz 48 kHz 96 kHz 192 kHz 96 kHz 88 2 kHz 96 kHz 44 1 kHz 88 2 kHz 176 4 kHz 88 2 kHz 96 kHz 96 kHz 48 kHz 96 kHz 192 kHz 96 kHz 176 4 kHz 96 kHz 44 1 kHz 88 2 kHz 176 4 kHz 88 2 kHz 192 kHz 96 kHz 48 kHz 96 kHz 192 kHz 96 kHz Supported Samples Rates at 48 kHz SRC Clock Source AES EBU Corresponding Input fs AES E...

Page 9: ...This can also be set to x1 x2 or x4 of this base sample rate 48k Tip Setting the output SRC to IN will set this AES port s output to clock from the corresponding input rather than the console clock This is useful if the external device has issues clocking to an external clock This setting will allow the external device to use its internal clock with the Live console s AES SRC locked to the externa...

Page 10: ... 10 Stereo iJack Input 11 Power USB Port 8b Mains Power Inlet Redundant PSU option available 1 Local MADI 4 Ports Coaxial 2 Local SC Fibre MADI FX Loop 6 Optional Blacklight II Neutrik opticalCON DUO Connectors 0 or 2 connectors 3a VGA Monitor for Ext Overview 7 USB 8a Analogue Mic Line IP 1 12 4 Analogue Line OP 1 12 4 AES 1 8 4pr In 4pr Out 5 Optional Dante Interface 9 Cat 5e Network 14 Wordcloc...

Page 11: ...flight case 130 kg 286 6 lbs Acoustic Noise With non redundant PSU NR23 With redundant PSUs NR25 Typical Power 360 W Ratings With non redundant PSU 100 240 V AC 50 60 Hz 10 0 5 0 A With redundant PSUs 100 240 V AC 50 60 Hz 8 0 4 0 A Console Dimensions upper figures in millimetres lower figures in feet inches A DXF drawing is available from SSL Plan View Side View ...

Page 12: ...o iJack Input 11 Power USB Port 8b Mains Power Inlet Switch 1 Second Mains Power Inlet Switch 1 Local MADI 6 Ports Coaxial 2 Ports Fibre SC 2 Local SC Fibre MADI FX Loop 6 Optional Blacklight II Neutrik opticalCON DUO Connectors 0 or 2 connectors 3a VGA Monitor for Ext Overview 7 USB 8a Sync Panel details on page 22 Analogue Mic Line IP 1 12 4 Analogue Line OP 1 12 4 AES 1 8 4pr In 4pr Out 5 Dante...

Page 13: ...Dimensions Weight without flight case 85 kg 188 lbs Weight with flight case 210 kg 463 lbs Acoustic Noise NR40 Typical Power 460 W Ratings 100 240 V AC 50 60 Hz 10 0 5 0 A Console Dimensions upper figures in millimetres lower figures in inches A DXF drawing is available from SSL Plan View Side View ...

Page 14: ... 4 Jack Headphone B Solo Ch 2 10 Mains Power Inlet Switch 1 Second Mains Power Inlet Switch 1 Local MADI 2 Local SC Fibre MADI FX Loop 6 Optional Blacklight II Neutrik opticalCON DUO Connectors 0 or 2 connectors 3a VGA Monitor for Ext Overview 7 USB 8a Sync Panel details on page 22 Analogue Mic Line IP 1 16 4 Analogue Line OP 1 16 4 AES 1 8 4pr In 4pr Out 5 Dante Interface 9 L350 only Optional X L...

Page 15: ...mensions Weight without flight case 86 kg 190 lbs Weight with flight case 176 kg 388 lbs Acoustic Noise NR30 Typical Power 450 W Ratings 100 240 V AC 50 60 Hz 10 0 5 0 A Console Dimensions upper figures in millimetres lower figures in feet inches A DXF drawing is available from SSL Plan View Side View ...

Page 16: ...USB Port 8b Mains Power Inlet Switch 1 Second Mains Power Inlet Switch 1 Local MADI 6 Ports Coaxial 2 Ports Fibre SC 2 Local SC Fibre MADI FX Loop 6 Optional Blacklight II Neutrik opticalCON DUO Connectors 0 or 2 connectors 3a VGA Monitor for Ext Overview 7 USB 8a Sync Panel details on page 22 Analogue Mic Line IP 1 12 4 Analogue Line OP 1 12 4 AES 1 8 4pr In 4pr Out 5 Dante Interface 9 Optional X...

Page 17: ...ons Weight without flight case 85 kg 188 lbs Weight with flight case 210 kg 463 lbs Acoustic Noise Typically NR30 Typical Power 460 W Ratings 100 240 V AC 50 60 Hz 10 0 5 0 A Console Dimensions upper figures in millimetres lower figures in feet inches A DXF drawing is available from SSL Plan View Side View ...

Page 18: ...onal Analogue Mic Line IP 17 32 4 Optional Analogue Line OP 17 32 4 Optional AES 9 16 4pr In 4pr Out 5 Standard Analogue Mic Line IP 1 16 4 Standard Analogue Line OP 1 16 4 Standard AES 1 8 4pr In 4pr Out 5 Local MADI A 2 Local MADI B 2 Local SC Fibre MADI FX Loop 6 Optional Blacklight II Neutrik opticalCON DUO Connectors 0 or 2 connectors 3a VGA Monitor for Ext Overview 7 USB 8a Sync Panel detail...

Page 19: ...imensions Weight without flight case 90 kg 198 lbs Weight with flight case 195 kg 430 lbs Acoustic Noise NR40 Typical Power 460 W Ratings 100 240 V AC 50 60 Hz 10 0 5 0 A Console Dimensions upper figures in millimetres lower figures feet inches A DXF drawing is available from SSL Plan View Side View ...

Page 20: ...10 Mains Power Inlet Switch 1 Second Mains Power Inlet Switch 1 Local MADI 6 Ports Coaxial 2 Ports Fibre SC 2 Local SC Fibre MADI FX Loop 6 Optional Blacklight II Neutrik opticalCON DUO Connectors 0 or 2 connectors 3a VGA Monitor for Ext Overview 7 USB 8a Sync Panel details on page 22 Analogue Mic Line IP 1 12 4 Analogue Line OP 1 12 4 AES 1 8 4pr In 4pr Out 5 Dante Interface 9 Optional X Light Ne...

Page 21: ...sions Weight without flight case 85 kg 188 lbs Weight with flight case 210 kg 463 lbs Acoustic Noise Typically NR30 Typical Power 460 W Ratings 100 240 V AC 50 60 Hz 10 0 5 0 A Console Dimensions upper figures in millimetres lower figures in inches A DXF drawing is available from SSL Plan View Side View ...

Page 22: ...nections Key The LTC output is a reshaped timecode feed derived from the LTC input and the MIDI output a reclocked duplicate of incoming MTC The console does not offer LTC to MTC or MTC to LTC conversion USB 8a N C Future Expansion MIDI 15a LTC 17 Wordclock 13 AES Reference 16 GPIO In Out 19b Connectivity Network 14 Video Reference 18 ...

Page 23: ...allation Information www solidstatelogic com Page 23 of 45 Remote Tile Rear Connections Mains Power Inlet 1 USB B Connection 8c Connects to console via USB A B Cable up to 5m without active repeaters Connections Key ...

Page 24: ...7 kg 21 4 lbs Weight with flight case 19 7 kg 43 5 lbs Acoustic Noise Fan does not start until external temperatures reach approximately 40 ºC Above 40 ºC NR33 Typical Power 100 W Ratings 100 240 V AC 50 60 Hz 1 8 1 0 A Dimensions upper figures in millimetres lower figures in feet inches A DXF drawing is available from SSL Plan Side View ...

Page 25: ...PSU Status MADI Link Status Clear Attention LEDs Mains Power Inlet 1 Primary MADI Coaxial 2 Maintenance USB Port 24 MIDI 15b Local Wordclock 13 GPIO In Out 19a Redundant MADI Coaxial 2 Additional MADI outputs 2 Optional Analogue Mic Split Outputs 4 Local Setup Controls 20 All MADI Outputs carry common data MADI outputs 3 4 can be used as MADI output only streams for other devices ...

Page 26: ...Splits shown on rear picture Front Rear ML O 32 5U Line Output Stagebox Special order outputs only version of the ML 32 32 See ML 32 32 for relevant connector details Front Rear ML 32 32 Weight Dimensions Height 5U 223 mm 8 75 inches Depth 446 mm 17 5 inches Width 483 mm 19 inches Weight 17 kg inc optional Split Outputs Power 300 W Ratings 100 240 V AC 50 60 Hz 3 0 1 5 A Acoustic Noise Typically N...

Page 27: ...05 mm 12 inches Width 483 mm 19 inches Weight 6 2 kg Power 60 W Ratings 100 240 V AC 50 60 Hz 0 6 0 4 A 32 AES Digital Inputs Outputs 16 AES Pairs Arranged as In Out Pairs 5 Mains Power Inlet 1 Primary MADI Coaxial Connectors 2 Maintenance USB Port 24 MIDI 15b Local Wordclock 13 GPIO In Out 19a Redundant MADI Coaxial Connectors 2 Additional MADI outputs 2 Local Setup Controls 20 ...

Page 28: ...s Key BLII D Weight Dimensions Height 2U 89 mm 3 5 inches Depth 305 mm 12 inches Width 483 mm 19 inches Weight 6 5 kg Power 60 W Ratings 100 240 V AC 50 60 Hz 0 6 0 4 A Blacklight II Neutrik opticalCON DUO Connectors 3a Coaxial MADI Connections 2 Maintenance USB Port 24 Mains Power Inlet 1 Not in use Local Setup Controls ...

Page 29: ...on on LED status meanings please see livehelp solidstatelogic com Help DanteBridges html BLII Bridge Weight Dimensions Height 1U 44 5 mm 1 75 inches Depth 340 mm 13 4 inches Width Including Rack Ears 483 mm 19 inches Weight 4 5 kg 9 9 lbs Power 60 W Ratings 100 240 V AC 50 60 Hz 1 8 1 0 A Acoustic Noise Typically NR31 PSU Sync Status Primary Secondary Dante 21 Mains Power Inlet 1 BLII LC Fibre 3b ...

Page 30: ...idstatelogic com Help DanteBridges html X Light Bridge Weight Dimensions Height 1U 44 5 mm 1 75 inches Depth 340 mm 13 4 inches Width Including Rack Ears 483 mm 19 inches Weight 4 8 kg 10 6 lbs Ratings 50 W Power 100 240 V AC 50 60 Hz 0 4 0 2 A Acoustic Noise Typically NR23 PSU Sync Fibre Status X Light Neutrik opticalCON QUAD Connectors 22 Mains Power Inlet 1 2 x Dante Interface 1 x Console Link ...

Page 31: ...d here edesk belden com products techdata metric pdf 1694F pdf SSL recommends that cable assemblies should have a 360º connection between cable shield and the connector in order to maintain electromagnetic compatibility Cables runs between Console or Blacklight MADI Concentrators and Stageboxes up to 75 meters Higher quality cable connections can support up to 100 meters 75 m Drum of correct cable...

Page 32: ...mum length 300 m quality cables connections and no intermediate connections 4 Analogue Analogue Inputs and Outputs on 3 pin XLR connections Dimensions Cable Dia 19 x 60 mm approx 8 12 mm typical Pinout for balanced audio Pin 1 Screen Ground Pin 2 Hot ve Pin 3 Cold ve 5 AES EBU AES3 Inputs and Outputs on 3 pin XLR connections IEC 60958 Type I Dimensions Cable Dia 19 x 60 mm approx 8 12 mm typical P...

Page 33: ...ne Output Pinout Sleeve Screen Ground Ring Right Tip Left 11 3 5 mm Jack Input 3 5 mm stereo jack socket for phones or portable media players 12 Reserved 13 Wordclock BNC connections to IEC 60169 8 75 Ω Characteristic Impedance unterminated internally Wordclock Output is active when no Input is present Wordclock Output follows console selected reference source for use as a local Wordclock referenc...

Page 34: ...ode LTC in and out using Balanced XLR connections Dimensions Cable Dia 19 x 60 mm approx 8 12 mm typical Pinout for LTC In and Out Pin 1 Screen Ground Pin 2 Hot ve Pin 3 Cold ve 18 Video Reference BNC connectors to IEC 60169 8 75 Ω Characteristic Impedance Analogue video 1 Vp p PAL NTSC Composite B B 19a Stagebox GPIO Connections Connector Type 25 Way D Type Female Combined Inputs Outputs Dimensio...

Page 35: ... 3A 17 Input 4B 23 Output 3B 5 Input 5A 11 Output 4A 18 Input 5B 24 Output 4B 6 Input 6A 12 Output 5A 19 Input 6B 25 Output 5B 13 12V 450mA maximum 19b Console GPIO Connections Connector Type 25 Way D Type Male Inputs and Female Outputs Dimensions Cable Dia 55 x 15 mm approx 8 mm typical Screwlock thread 440 UNC 12 opto isolated GP input and 12 relay closure outputs 1 2 3 4 5 6 7 8 9 10 11 12 13 1...

Page 36: ...17 Input 4B 23 Input 10B 5 Input 5A 11 Input 11A 18 Input 5B 24 Input 11B 6 Input 6A 12 Input 12A 19 Input 6B 25 Input 12B 13 0V GP Output D type Female Pin Description Pin Description 1 Output 1A 7 Output 7A 14 Output 1B 20 Output 7B 2 Output 2A 8 Output 8A 15 Output 2B 21 Output 8B 3 Output 3A 9 Output 9A 16 Output 3B 22 Output 9B 4 Output 4A 10 Output 10A 17 Output 4B 23 Output 10B 5 Output 5A ...

Page 37: ...ce to MADI Wordclock or internal inputs MADI LED colour meanings are as follows Green Main and Redundant are both locked Flashing Red and Green Only one MADI receiver is locked Red Neither Main or Redundant are locked Off Stagebox is clocking from its internal clock source 21 Dante SFP Cages 1 pair of Dante network connections SFP cages can be fitted with RJ45 SFPs or singlemode multimode fibre 22...

Page 38: ... temperature of the console by several degrees SSL recommends that if dust guards are fitted the console should not be operated in an external ambient temperature in excess of 30 C Typical Installation Diagrams Simple Single System L550 Control Surface shown provides 32 analogue IO 16 AES IO 16 MADI ports plus MADI FX Loop at FOH position 2 off ML 32 32 stageboxes provide 64 Mic Line inputs and 64...

Page 39: ...ff additional I 32 stageboxes provide an additional 96 Mic Line inputs 1 off additional D 32 32 AES boxes provide 32 AES digital IO Coaxial MADI connected IO 1 off ML 32 32 stageboxes provide 32 Mic Line inputs and 32 line outputs on stage 1 off additional D 32 32 AES boxes provide 32 AES digital IO Total remote IO of 128 Mic Line Inputs 32 Line Outputs 64 AES IO 36 GP inputs 30 GP Outputs D 32 32...

Page 40: ...Console is connected to the TX only connection from MADI ports 3 4 FOH console controls the Mic Amp Gain Monitor console uses Gain Sharing to adjust local levels 1 off additional D 32 32 AES boxes provide 32 AES digital IO to FOH console 1 off ML O 32 stageboxes provide 32 line outputs on stage from Monitor console Total remote IO of 96 Mic Line Inputs 32 Line Outputs 32 AES IO 30 GP inputs 25 GP ...

Page 41: ...ons to B port of the BL II D Blacklight MADI Concentrator FOH console controls the Mic Amp Gain Monitor console uses Gain Sharing to adjust local levels 1 off BLII D Blacklight II MADI concentrator provides 4 redundant on stage MADI ports connected to 3 off additional I 32 stageboxes provide an additional 96 Mic Line inputs 1 off additional D 32 32 AES boxes provide 32 AES digital IO Coaxial MADI ...

Page 42: ...SSL Live Installation Information www solidstatelogic com Page 42 of 45 Optional Console Stand Console Dimensions with optional stand figures in millimetres L550 Models SSL part 62A7000XL ...

Page 43: ...SSL Live Installation Information www solidstatelogic com Page 43 of 45 L200 and L350 L450 L650 Models SSL part 62A7300XL ...

Page 44: ...SSL Live Installation Information www solidstatelogic com Page 44 of 45 L450 and L650 Models SSL part 62A7400XL ...

Page 45: ...ademarks of Audinate Pty Ltd All other product names and trademarks are the property of their respective owners and are hereby acknowledged No part of this publication may be reproduced in any form or by any means whether mechanical or electronic without the written permission of Solid State Logic Oxford OX5 1RU England As research and development is a continual process Solid State Logic reserves ...

Reviews: