11
6.2 Installing the system
Mounting the triangles
•
While maintaining the planned
spacing, arrange the triangles so
they are parallel, and fix them
with the designated connecting
materials.
Fixing the X-stones
•
Fix two X-stones per triangle
(see point 4.1 Dimensions) to the
support rail of the triangle at the
specified points. Take care to
observe the differing alignment of
the X-stones for portrait or
landscape installation (see
illustration on the right).
•
Insert the Quickstone into the
profile channel so that the form
of the Quickstone fits perfectly
into the profile. The bolt may not
protrude beyond the lower edge
of the Quickstone.
•
Fasten the Quickstone loosely
with 2 bolt turns.
•
Put the X-stone in the desired
position and line it up
transversely to the support rail.
•
Tighten the bolt just enough
so that the X-stone does not slide
down. Do not tighten completely.
Material damage due to improper mounting
Improperly fastened X-stones may slip or rip out.
•
All Quickstone connections must be mounted according
to instructions.
•
After mounting, check that the bolted connections are tight.
CAUTION
Portrait installation
Landscape installation
Material damage due to inappropriate material selection
Inappropriate fixation material can cause the triangles to rip out, roof damage and leakage.
•
Select appropriate fixation material according to the location, roof state, and system design.
Material damage from improper mounting
Improperly fixed triangles can rip out and result in leaks.
•
All attachments should be of professional quality.
•
After mounting, ensure that the fixation is correct.
WARNING
WARNING
1