background image

 

 

 

 
 
INSTALLATION & ASSEMBLY INSTRUCTIONS - WINDOW MOUNTING 

REMOVE CHASSIS 

1.  Pull down the front panel and remove the filter. (See Fig. 3) 
2.  Lift the front panel upwards to remove and place to the side. 

3.  Locate the four faceplate screws and remove. These screws will need to be re-installed prior to mounting the air con- 

ditioner. (See Fig. 4) 

4.  After removing the screws, gently pull away the faceplate from the air conditioner cabinet. Remove the ground screw 

and save for reinstallation later. (See Fig. 5 & 6) 

 

5.  Remove the two screws from top of the unit. (See Fig. 7) Hold the cabinet while pulling on the base handle, and care- 

fully remove the unit.

 

 

 

Fig. 3 

Fig. 4 

Fig. 5 

Fig. 6 

Fig. 7 

INSTALLATION

ION 

Summary of Contents for WM1-15E-01

Page 1: ...Electronic Window Air Conditioner Operating Instructions V170124 Models WM1 15E 01 15 400 BTU WM1 18E 01 18 300 BTU WM1 24E 01 24 700 BTU...

Page 2: ...ortant to us Please pay attention to all safety messages outlined in this owner s manual WARNING To reduce the risk of fire electrical shock or injury when using your air conditioner follow the follow...

Page 3: ...al The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet The LED light will turn on 2 Press TEST Button circuit s...

Page 4: ...Bottom Rail 1 Owner s Manual 1 Weather Insulation Board 2 CURTAIN CURTAIN LOCK FOAM SEAL FOR BOTTOM RAIL SCREWS AND LOCKNUTS FRAME ASSEMBLY WINDOW SUPPORT BRACKET Weather Insulation Board SILL ANGLE B...

Page 5: ...ns W x H x D 23 625 x 17 75 x 25 375 Package Dimensions W x H x D 26 125 x 20 x 30 5 Net Gross Weight Lbs 110 121 Refrigerant Type R 410A Plug Type NEMA 5 15P Model WM1 18E 01 WM1 24E 01 Power Supply...

Page 6: ...NT TEST TO THE INFORMA TION AND THE SPECIFICATIONS PRESENTED HEREWITHIN WARNING Avoid fire hazard or electronic shock DO NOT use an extension cord or an adapter plug DO NOT remove any prong from the p...

Page 7: ...ood to the sill The board or wood piece should have a depth of at least 1 1 2 Make sure the board or piece of wood is approximately 1 2 higher than the storm window frame This will allow the air condi...

Page 8: ...hese screws will need to be re installed prior to mounting the air con ditioner See Fig 4 4 After removing the screws gently pull away the faceplate from the air conditioner cabinet Remove the ground...

Page 9: ...side 3 Fasten the curtains to the unit with short screws Fig 10 Window Frame 1 4 Top Rail Bottom Rail Fig 10 Weather Insulation Board Installation NOTE The Weather Insulation Board adds an extra layer...

Page 10: ...w Insert the sash seal into space between the upper and lower sashes MARK 2 Attach the right angle safety lock as shown below 2 Assemble the sill angle brackets to the support brack ets at the marked...

Page 11: ...reference Extend the Curtain Panels 1 Carefully raise the window to expose the curtain panel and panel frame Extend the curtain panels to fill the window opening 2 Place the curtain lock between the...

Page 12: ...an Speed Use the fan speed button to change the fan speed Choose between high medium and low 6 Mode Button Press the MODE button to cycle through the various modes Auto Sleep Energy 7 Auto on Timer Wh...

Page 13: ...ve Remote colors may differ from image above Battery Size AAA NOTE Do not mix old and new batteries or different types of AAA batteries LCD Display MODE SLEEP FAN HIGH ENERGY SAVER FAN MED TIMER FAN L...

Page 14: ...ep operating the same temperature until the sleep mode is turned off 6 ENERGY SAVER Press the ENERGY SAVER button to turn on Energy Saver mode When the unit is in Energy Saver mode the energy saver li...

Page 15: ...aver Mode When the Energy Saver mode is ON the fan will cycle on and off with the compressor This re sults more winder variations of room tempera ture and humidity Normally it is used when the room is...

Page 16: ...nt panel of the air conditioner may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid soap Rinse thoroughly with a damp cloth and wipe dry Ne...

Page 17: ...y engaged discontinue use of the air conditioner and contact a qualified service technician The Air Conditioner does not cool as it should Airflow is restricted Make sure there are no curtains blinds...

Page 18: ...ghtly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture removed from the air is draining into the base pan This is normal for a short period in areas with...

Page 19: ...sions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus...