background image

 1

3

 

 

7) 

SWING

 - To turn on oscillation, press the 

SWING 

button on the remote control when the unit is in air 

conditioner mode, fan mode, and dehumidifier mode. The remote control  will show an arrow ► by to 
the “SWING” icon on the remote control LCD display. Once you press 

SWING, 

the louvers on the 

unit will oscillate left and right.  

OPERATING THE UNIT  
 
Air Conditioner Mode 

1)  Install the exhaust hose and window kit properly (see pages 7 & 8).  
2)  Plug the Power Cord into an electrical outlet. 
3)  Turn on the unit by pressing the 

POWER 

button. 

4)  Press the Mode button until the air conditioner mode icon lights up on the control panel display. 
5)  Press the ▲ or ▼ until the desired room temperature appears on the control panel display. The tem-

perature ranges from 64

°

F - 90 

°

F ( 18

°

C - 32

°

C). 

6) Select the desired fan speed by pressing the 

FAN 

button by using the Remote control. 

 

NOTE: 

During hot days, the unit will cool the room most efficiently by setting the temperature at the low-

est setting and the fan speed on high. Reducing the length of the exhaust duct, insulating the ex-
haust hose and window kit, and keeping direct sunlight to a minimum will also improve the cool-
ing efficiency.  

 

NOTE

When the unit is running on air conditioning mode, the exhaust hose is required and must be 
vented outside using the supplied window kit.

  

 

Dehumidifier Mode 

1)  Install the exhaust hose and window kit properly (see pages 7 & 8 ). 
2)  Plug the Power Cord into an electrical outlet. 
3)  Turn on the unit by pressing the 

POWER 

Button. 

4)  Press the 

MODE 

button until the dehumidifier mode icon lights up on the control panel display. 

 

NOTE:  

The unit operates at low fan speed during dehumidifier mode. The unit cools room slightly dur-  

ing the dehumidification process. Keep the windows and doors closed to aid the effectiveness of 
the unit in removing the moisture from the room.  

 

NOTE

When the unit is running on dehumidifier mode, the exhaust hose is required and must be   

vented outside using the supplied window kit.

  

 

NOTE: 

The unit will not perform in dehumidifier mode when the room temperature is lower than 61

°

F .  

 

Fan Mode 

1)  Plug the Power Cord into an electrical outlet. 
2)  Turn on the unit by pressing the 

POWER 

button on the control panel. 

3)  Press the 

MODE 

button until the fan mode icon lights up on the control panel display. 

4)  Select the fan speed by pressing the FAN button. 
 

NOTE: 

It is not necessary for the exhaust hose and window kit to be installed to operate the unit in fan 

mode.  
  

 

Summary of Contents for TM-PAC-08E3

Page 1: ...8 000 10 000 12 000 BTU Portable Air Conditioner Operating Instructions Model No TM PAC 08E3 TM PAC 10E3 V140306 3119233 Model No TM PAC 12E4 ...

Page 2: ... reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clearance space around this unit Do not block or cover air inlet or outlet grilles 4 The unit must be connected to a correctly grounded power supply 5 Do not start or stop the unit by inserting or ...

Page 3: ...Conditioner 1 Exhaust Hose 1 Exhaust Hose Connector 1 Window Kit Adapter 1 Window Kit Adapter Extension 1 Rubber Plug 2 Remote Control 1 AAA Batteries 2 Caster Lock 2 Window Kit Sliding Panels 3 Drainage Hose 1 Owner s Manual 1 PACKAGE CONTENTS SPECIFICATIONS The cooling capacity is measured at an ambient temperature of DB 86 F WB 78 F Noise level is measured at a distance of 3 28 ft away from the...

Page 4: ...hock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet 2 Press TEST Button circuit should trip cutting power to the air conditioner 3 Press RESET button for use If test button is pressed and unit can still be turned on...

Page 5: ...ound or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet The LED light will turn on 2 Press TEST Button circuit should trip cutting power to the air conditioner When this occurs 3 Press RESET button to restore power to the machine Once power is restored the LED light will turn on again ...

Page 6: ...6 Air Filter 7 Carry Handle 8 Air Exhaust Hose Discharge Opening 9 Condensation Drain Hole 10 Power Cord 11 Product Manual Not Shown 12 Exhaust Hose 13 Exhaust Hose Connector 14 Window Kit Adapter 15 Remote Control 16 Caster Locks 17 Rubber Plug 18 Window Kit 19 Window Kit Adapter Extension 20 Drainage Hose ...

Page 7: ... 4 6 ft long approximate length MOUNTING THE EXHAUST HOSE Choose a suitable location near a grounded electrical outlet and suitable window or door Remove packaging and locate components Extend both ends of the exhaust hose approximately 6 inches Screw the window kit adapter onto one end of the exhaust hose counter clockwise Screw the exhaust hose connector onto the other end of the exhaust hose co...

Page 8: ...8 WINDOW KIT INSTALLATION ...

Page 9: ...s free from gaps and or air pockets when taking measurements 3 Insert the rubber plugs into the holes that correspond with the width that your window requires to ensure that there are no gaps or air pockets in the window kit assembly after installation 1 Parts A Panel B Panel with one exhaust hose opening C Panel without exhaust hose opening D Rubber plug to lock window kit in place ...

Page 10: ...ature setting Af ter the temperature is set the unit will display this temperature setting until it is changed by the user The temperature indicator display shows temperature in Fahrenheit Press and hold the Mode button for 20 seconds to switch between Celsius and Fahrenheit 4 Bucket Full When the unit cannot evaporate the collected moisture fast enough the excess water will collect in a backup wa...

Page 11: ...AY POWER BUTTON SLEEP BUTTON MODE BUTTON FAN SPEED OPERATING THE UNIT USING THE REMOTE CONTROL Remote Colors may differ from the image above SWING BUTTON TIMER TEMP DECREASE TIMER TEMP INCREASE C F BUTTON THIS BUTTON DOES NOT HAVE A FUNCTION ...

Page 12: ...perature Press the or to select your desired temperature setting The temperature on the LCD dis play on the remote control will increase or decrease accordingly Pressing the C F button will change the temperature select between C and F 5 SLEEP MODE To set Sleep mode make sure the unit is in Air Conditioner mode Dehumidifying mode or Auto mode Press the SLEEP Button on the remote control the remote...

Page 13: ...um will also improve the cool ing efficiency NOTE When the unit is running on air conditioning mode the exhaust hose is required and must be vented outside using the supplied window kit Dehumidifier Mode 1 Install the exhaust hose and window kit properly see pages 7 8 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER Button 4 Press the MODE button until the d...

Page 14: ...unit to aid in drainage into the pan Once the condensate tank is drained the unit will begin working within a few minutes The emergency condensate tank is approximately 1 5 Liters of water Another option is to pur chase a small hose from a hardware store that can fit around the 9 16 drain plug on the back of the unit and drain the unit into a gravity drain or larger pan for continuous drainage It ...

Page 15: ...y dried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the unit 1 Empty any excess w...

Page 16: ...t hose correctly keeping it as short and free of curves as possible Check and remove anything obstructing air discharge During operation there is an unpleasant smell in the room Air filter is dirty Remove air filters clean and re install Air conditioner does not oper ate after restarting the unit The internal compressor safety de vice prevents the unit from being restarted until three minutes have...

Page 17: ...17 SELF DIAGNOSIS SYSTEM MALFUNCTION CODES SELF DIAGNOSIS The appliance has a self diagnosis system to identify a number of malfunctions Error messages are displayed on the appliance display ...

Page 18: ... parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Home Comfort Freight and Insurance cost for the warranty service Filter and Accessories ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS HOME COMFORT DISCLAIMS ANY LIABILITY FOR CONSEQUENT...

Reviews: