TECHNICAL SPECIFICATIONS 

 

MODEL

 

PH1-14R-03

 

KY-34

PH1-10R-03

 

Cooling Capacity

 

14,000 BTU/Hr

 

12,000 BTU/Hr

 

10,000 BTU/Hr

 

Heating Capacity 

14,200 BTU/Hr 

12,200 BTU/Hr 

10,200 BTU/Hr 

Dehumidifying Capacity 

 

65 pts/day

 

63 pts/day

 

60 pts/day

 

Cooling

 

1390 W

 

1340 W

 

1180 W

 

Power Consumption

 

Heating 

1180 W 

1090 W 

1000 W 

Air Flow Volume 

 

328CFM

 

280CFM

 

280CFM

 

Power Source

 

115 V / 60 HZ

 

115 V / 60 HZ

 

115 V / 60 HZ

 

Cooling  12 A   

11.7 A   

9.8 A 

Rated Current 

Heating 

  9.8 A 

9.5 A 

8.8 A 

Sound Pressure Level

 

<49 db(A)

 

<49 db(A)

 

<49 db(A)

 

Weight

 

80 lbs

 

80 lbs

 

78 lbs

 

Dimensions

 

14.4 x 22.4 x 30.5 inches 
 (WxDxH)

 

14.4 x 22.4 x 30.5 inches 
 (WxDxH)

 

14.4 x 22.4 x 30.5 inches 
 (WxDxH)

 

Refrigerant

 

R22

 

R22

 

R22

 

 
 

DISCLAIMER 

ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL 
ARE THE PRESENTATION OF THE MANUFACTURER.  SOLEUS INTERNATIONAL HAS NOT 
CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED 
HEREWITHIN. 

 

Summary of Contents for KY-34

Page 1: ...Portable Air Conditioner Dehumidifier Heater and Fan utilizing Heat Pump Technology OWNER S MANUAL Model KY 34 Please read owner s manual carefully before operating unit 3046364...

Page 2: ...NELAND MULTI COLOR DISPLAY 9 CONTROL PANEL FUNCTIONS 10 OPERATION USING THE CONTROL PANEL 10 COOLING 10 DEHUMIDIFYING 11 FANNING 11 HEATING 11 AUTO MODE 11 SLEEP MODE 12 REMOTE CONTROL OPERATION 12 MA...

Page 3: ...operating as an air conditioner this unit is designed for spot cooling or cooling a room no larger than 550 square feet with a standard eight foot ceiling height When using this appliance always exer...

Page 4: ...upervision is necessary when the unit is used near children The unit in not intended for use by children 10 Do not insert anything into the air outlet Do not obstruct air inlet or outlet grills 11 Do...

Page 5: ...t grounded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check...

Page 6: ...Cable power cord and plug BACK A Hot air outlet grill B Lower air inlet grill ACCESSORIES Flexible exhaust hose with adapters 3 piece set stretches from 14 1 4 to 60 5 8 36cm to 150cm Window exhaust...

Page 7: ...ST HOSE Slide the square end of the exhaust duct over the hot air outlet on the back of the unit The exhaust hose should be kept as short and straight as possible Prevent any sharp bends in the exhaus...

Page 8: ...sliding door and adjust the length of the window kit to fit the opening Mark and cut down a single panel of the window kit if necessary 2 Place the window kit between the window and the window frame a...

Page 9: ...ases the room temperature timer hours Button This button increases the room temperature timer hours Power Button Press this button to turn the unit on or off MODE Button Press this button to select am...

Page 10: ...o set the auto stop time press the Timer Off button and the multi color display will show a flashing Press the and buttons to change the clock to the desired time for the unit to automatically stop Th...

Page 11: ...en the unit is running on fan mode the exhaust hoses are inoperative and are not required HEATING 1 Plug the power cord into a grounded outlet 2 Turn on the unit by pressing the On Off button on the c...

Page 12: ...n 6 When in dehumidify mode the temperature will not change NOTE If the unit is turned off during cooling dehumidifying or heating and then restarted there will be a 3 minute delay before the compress...

Page 13: ...r container is full 2 Place the drain pan accessory under the drainage port at the back of the unit 3 Remove the rubber plug from the drain hole The condensate water will drain out automatically When...

Page 14: ...ide the filters out from the side of the unit Immerse the filter gently in warm water with a mild detergent Rinse thoroughly and dry before replacing An unclean air filter reduces air volume The filte...

Page 15: ...at low Increase the fan speed Unit is noisy or vibrates Is the machine positioned unevenly on a level surface Place the unit on a level surface Is the voltage from the power source correct Use a prope...

Page 16: ...e 115 V 60 HZ 115 V 60 HZ 115 V 60 HZ Cooling 12 A 11 7 A 9 8 A Rated Current Heating 9 8 A 9 5 A 8 8 A Sound Pressure Level 49 db A 49 db A 49 db A Weight 80 lbs 80 lbs 78 lbs Dimensions 14 4 x 22 4...

Page 17: ...d by wear 4 Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus International Inc 5 Freight and Insurance cost for the warranty service ALL WARRANTIES I...