background image

Summary of Contents for KY-320

Page 1: ......

Page 2: ...BEFORE USE 3 CONTROL PANEL AND LCD DISPLAY 5 CONTROL PANEL FUNCTIONS 6 OPERATION USING CONTROL PANEL 7 OPERATION USING REMOTE CONTROLLER 8 CONDENSATEWATERDRAINAGE 11 MAINTENANCE 12 TROUBLESHOOTING 14...

Page 3: ...use your portable air conditioner please read this operation manual carefully 1 Never use or store gasoline or other flammable vapor or liquid near this unit 2 Maintain at least 10 25 CM clearance sp...

Page 4: ...ackView control panel upper air outlet handle lower air inlet grille Signal Receptor upper air inlet grill with filter power cord hot air exhaust outlet lower air inlet grille water tank continuous dr...

Page 5: ...airconditionerfollowing theseprocedures a Hold the water tank and draw it out slowly b Removewatertankfloatlidandpackingmaterial from the water tank c Insert the float lid into the water tank by inser...

Page 6: ...haust duct for a window or sliding door hot air outlet installation NOTE In order to increase the efficiency the exhaust duct should be keep as short and straight as possible The exhaust hose can be c...

Page 7: ...on if necessary NOTE Whenusingthewindowkitonawindoworslidingdooritwillcausethewindoworslidingdoor not to be properly closed and locked Additional security measurements should be taken CONTROL PANEL AN...

Page 8: ...re before selecting the operational mode 5 TimerControl Set time to start or to stop the unit When the unit is running the timer will shut off the unit in the number of hours set When the unit is off...

Page 9: ...Mode a Press the Mode Button until the Auto appears on the LCD display In the Auto Mode the factory set microprocessor controls the temperature and fan speed for optimal comfort NOTE Duringhotdays th...

Page 10: ...n NOTE When the unit is running on fan mode the exhaust duct is inoperative and is not required OPERATION USING REMOTE CONTROLLER The remote controller provided with the unit may operate this portable...

Page 11: ...e Transmit key to set time 2 CoolingOperation a Press the On Off key to turn on the remote controller b Press the Mode key until the LCD displays COOL c Press either of key of the Temperature key unti...

Page 12: ...eration a Press the On Off key to turn on the remote controller b Press the Mode key unit FAN appears on the LCD display c Press the Fan Speed key until the LCD displays the desired fan speed d Presst...

Page 13: ...eep alarm will sound eight times for 15 seconds The compressorstopsrunningandthefanwillcontinuetoruninthesetspeedforthreeminutesbefore theentireunitautomaticallyshutsoff When the water tank is full ta...

Page 14: ...wnward c Hold down the drainage spout and then connect the drainagetubingintodrainagespout d Place the other end of the drainage tubing into either an external water tank or the receptor of a condensa...

Page 15: ...oles in the unit case Push the cover back intoitsoriginalposition f If the filter is torn or unusable order a new filterbycallingthecontactsectionofthis manual 2 Case a Keep the unit from being expose...

Page 16: ...his unit provides spot cooling or cooling for a room no larger than 350 square feet with standard ceil ingheight There is frost on the evaporator The unit will defrost automatically and return to oper...

Page 17: ...ATION OF THE MANUFACTURER SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRE SENTED HEREWITHIN CONTACT INFORMATION Contact For Optional and Spare Par...

Page 18: ...16 ELECTRIC PRINCIPLE DRAWING KY 32U...

Page 19: ...S WARRANTY DOES NOT COVER 1 Damage accidentalorotherwise totheairconditionerwhileinthepossessionofaconsumer not caused by a defect in material or workmanship 2 Damagecausedbyconsumermisuse tampering o...

Page 20: ...re not grounded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to c...