2

To avoid death, personal injury or property

damage due to electrical shock:

• 

 Observe all local codes and ordinances.

  Disconnect electrical power to unit before servicing.

•  

Ground appliance properly.

•  

Check with a qualified electrician if you are not

    sure this appliance is properly grounded.

•  

DO NOT ground to gas line.

•  

DO NOT ground to cold water pipe if pipe is

    interrupted by plastic, non-metallic gaskets, or
    other insulating (non-conducting) materials.

•  

DO NOT modify plug on power cord. If plug

    does not fit electrical outlet, have proper outlet
    installed by qualified electrician.

•  

DO NOT have a fuse in the neutral or ground

    circuit. A fuse in the neutral or ground circuit
    could result in an electrical shock.

•  

DO NOT use an extension cord with this appliance.

•  

DO NOT use an adapter plug with this appliance.

•  

DO NOT pinch power cord.

  DO NOT REMOVE warning tag from power cord.

WARNING

Electrical Requirements

Grounding Instructions

This appliance is equipped with a three-prong grounding plug
for protection against possible shock hazards.  If a two-prong
wall receptacle is encountered, the customer is required to
contact a qualified electrician and have the two-prong wall
receptacle replaced with a properly grounded three-prong
wall receptacle in accordance with the National Electrical
Code.
Room air conditioners are designed to operate according to
requirements on the nameplate and as shown in Table 1.
Fuse or circuit breaker ratings must be according to the fuse
instruction label and as shown in Table 1.  Do not plug models
marked “Use on Single Outlet Circuit Only” into a circuit with
another appliance or light fixture.

Receptacle Wiring

Receptacle wiring must be of adequate size for unit. Refer
to unit identification plate for exact power requirements.
Minimum size of wiring, based on power requirements, is:
Units up to 20 amps:

12 gauge

20–30 amp units:

10 gauge

LCDI or AFCI Power Cords

Underwriters Laboratories (UL) and the National Electric
Code (NEC) now require power cords that sense current
leakage and can open the electrical circuit to the unit.  In the

HIGH TEMPERATURE STRESS HAZARD

This room air conditioner is not meant to

provide unattended cooling or life support

for persons or animals that are unable to

react to failure of the product.
The failure of an unattended air conditioner

may result in extreme heat in the cond-

itioned space causing overheating or

death of persons or animals.
Precautions must be taken to ward off or

guard against such an occurrence.

WARNING

Unpacking

Unpack and visually inspect the unit.  Report any damage to
the delivering carrier immediately.  Remove and discard all
packing material.  On some models the air conditioner front
and/or mounting kit hardware may be packed separately.
Record the model, serial and manufacturing numbers of your
unit in the space provided below.  This information is found on
a nameplate visible after the front of the air conditioner has
been removed.  The rated voltage, amperage and capacity for
your specific model can also be found on this nameplate.
Read the warranty packaged with the unit.  Keep the warranty
and a copy of your sales receipt for future reference.  You may
also want to record in the space provided the date purchased
and the selling dealer.

OWNER'S PRODUCT IDENTIFICATION

MODEL NUMBER

SERIAL NUMBER

MANUFACTURING NUMBER

Owner's Name

Address

City

State

Zip

        /        /   

Date of Purchase

Authorized Dealer

Address

City

State

Zip

(       )

Phone Number

Summary of Contents for KC-45H

Page 1: ...BTU Room Air Conditioner with Heat Pump OPERATING AND INSTALLATION MANUAL Model KC 45H Thank you for selecting Soleus Air To ensure proper operation please read this manual and keep it for future refe...

Page 2: ...UCTIONS 6 11 OPERATING CONTROLS 12 BEFORE CALLING SERVICE 13 WHEN SERVICE IS REQUIRED 14 ANY QUESTIONS 14 THROUGH THE WALL INSTALLATION INSTRUCTIONS 15 16 SPECIFICATION 17 WARRANTY 18 Thank you for se...

Page 3: ...arranty Service line at 1 888 8 SOLEUS If your problem cannot be resolved by phone contact an authorized Soleus Air brand servicer Contact and service will be at your expense Safety Information Be sur...

Page 4: ...appliance or light fixture ReceptacleWiring Receptacle wiring must be of adequate size for unit Refer to unit identification plate for exact power requirements Minimum size of wiring based on power r...

Page 5: ...separately Through the wallinstallationinstructionsareincluded with the outer case These models can be adapted to window installation by purchasing an optional mount ing kit RoomHeatPumps Heatpumpswo...

Page 6: ...lter Cleaning A dirty air filter reduces operating efficiency of unit Filter should be inspected at least once every week during opera tion Cleanfilterwithvacuumcleanerorwashinwarmwater and mild deter...

Page 7: ...outdoor coil surface This is the sound of water you hear during normal operation The water quickly evaporates on this warm surface and improves the efficiency of your air conditioner In normal condit...

Page 8: ...properly grounded 3 prong wall outlet Some models require 230 208 volt a c protected with a time delay fuse or circuit breaker These models should be installed on their own single branch circuit for...

Page 9: ...7 Installation Instruction Continuous...

Page 10: ...piece of wood to the stool WOOD PIECES WIDTH 2 LENGTH Long enough to fit inside the window frame THICKNESS To determine the thickness place a piece of wood on the stool to make it 1 2 higher than the...

Page 11: ...OW A Carefully slide the case into the window and center the case Lower the window behind the top mounting rail Pull the bottom of the case forward so that the bottom mounting rail is tight against th...

Page 12: ...weak or if the weight of the air conditioner falls between the studs in the wall F Extend the left and right accordion panels to the vertical window sashes Drill pilot holes and attach the top and bot...

Page 13: ...bottom corners and pull it forward Unhook it from its top hinges and set it aside F Using the tab pull up slightly on the filter to release it and pull it down and out 8 INSTALL THE AIR CONDITIONER IN...

Page 14: ...GH HEAT Filters and circulates room air with the fan running continuously on high speed Also heats while the compressor or electric heater is running Select this setting for maximum air circulation an...

Page 15: ...ature Control to cooler setting For heating turn Temperature Control to warmer setting NOISY UNIT Loose front on mounting assembly Weak building construction Water hitting fan blade Unit oversized for...

Page 16: ...quent failure of unit voids warranty Warranty details are contained in warranty certificate enclosed with unit Keep accurate records of service calls including what was done servicer s name and date o...

Page 17: ...m side to side Use wood shims between sides of case and finished opening especially where case is secured to opening to prevent warping or distorting Check installed case for distortion using carpente...

Page 18: ...se is properly positioned in opening use wood shims to fill any gaps between case and finished opening especially in area where case will be secured to opening Take care not to warp or distort case wh...

Page 19: ...e Highside 340 P S I Cooling AMPS 9 7 8 9 Cooling Watts 1955 2000 Cooling EER 9 0 Heating AMPS 8 8 8 3 Heating Watts 1790 1850 Heating EER 9 2 Electric Heat AMPS 15 6 16 Electric Heat Watts 3600 Air F...

Page 20: ...ect accident incorrect power line voltage fire flood or other Acts of God or normal wear and tear Warranty service must be performed by a qualified HVAC contractor Soleus maintains a centralized servi...

Reviews: