background image

 

1

 
 
 
            

Introduction 

 

Room air conditioners cool, dehumidify, and filter air inside your home.  Heat pump and electric heat models 
offer both heating and cooling.  Opening sections of manual provide general information for all room air 
conditioner models.  

Operating Controls 

section describes operation of controls for each model.  After reading 

the opening sections, turn to 

Operating Controls 

section and find the panel layout that matches the model of 

your unit. 
 
Read entire manual thoroughly before beginning installation and operation of your new room air conditioner.  
Be sure you have all necessary tools and materials on hand for the job.  Study illustrations to familiarize 
yourself with important details of the installation process. Review manual for operating instructions. 
 
 

NOTE 

1.  Mechanical experience is required to install air conditioner. 
2.  Installation can take from 1 to 3 hours, depending on installer’s knowledge and skill. 
3.  If you encounter problems during installation, call our Technical Support and Warranty Service line at 

1-888-8-SOLEUS.  If your problem cannot be resolved by phone, contact an authorized Soleus Air 
brand servicer. Contact and service will be at your expense. 

 

 
 

 

         

   

Safety Information 

 

Be sure electrical service is adequate for chosen model of air conditioner.  Complete electrical rating for unit is 
found on serial plate located behind front grille.  Electrical outlet must be close enough to unit for power cord to 
reach without strain.  Air conditioner should be the only appliance on individual circuit. 
 
For personal safety and to avoid possible damage to appliance or home, observe all safety instructions 
highlighted by symbol shown below. 
 
 
 

               RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.

 

 

After installing unit, reread instructions to ensure each step is complete and that all parts are fastened in place. 
For best results and to minimize installation time, perform all procedures in the order shown. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

To prevent heat related illness or death, do not use this device for unattended 
cooling of persons or animals unable to react to product failure. Failure of 
unattended air conditioner may result in extreme heat in area intended for cooling, 
causing heat related illness or death of persons or animals.

 

 

Summary of Contents for KC-45H

Page 1: ...BTU Room Air Conditioner with Heat Pump OPERATING AND INSTALLATION MANUAL Model KC 45H Thank you for selecting Soleus Air To ensure proper operation please read this manual and keep it for future refe...

Page 2: ...UCTIONS 6 11 OPERATING CONTROLS 12 BEFORE CALLING SERVICE 13 WHEN SERVICE IS REQUIRED 14 ANY QUESTIONS 14 THROUGH THE WALL INSTALLATION INSTRUCTIONS 15 16 SPECIFICATION 17 WARRANTY 18 Thank you for se...

Page 3: ...arranty Service line at 1 888 8 SOLEUS If your problem cannot be resolved by phone contact an authorized Soleus Air brand servicer Contact and service will be at your expense Safety Information Be sur...

Page 4: ...appliance or light fixture ReceptacleWiring Receptacle wiring must be of adequate size for unit Refer to unit identification plate for exact power requirements Minimum size of wiring based on power r...

Page 5: ...separately Through the wallinstallationinstructionsareincluded with the outer case These models can be adapted to window installation by purchasing an optional mount ing kit RoomHeatPumps Heatpumpswo...

Page 6: ...lter Cleaning A dirty air filter reduces operating efficiency of unit Filter should be inspected at least once every week during opera tion Cleanfilterwithvacuumcleanerorwashinwarmwater and mild deter...

Page 7: ...outdoor coil surface This is the sound of water you hear during normal operation The water quickly evaporates on this warm surface and improves the efficiency of your air conditioner In normal condit...

Page 8: ...properly grounded 3 prong wall outlet Some models require 230 208 volt a c protected with a time delay fuse or circuit breaker These models should be installed on their own single branch circuit for...

Page 9: ...7 Installation Instruction Continuous...

Page 10: ...piece of wood to the stool WOOD PIECES WIDTH 2 LENGTH Long enough to fit inside the window frame THICKNESS To determine the thickness place a piece of wood on the stool to make it 1 2 higher than the...

Page 11: ...OW A Carefully slide the case into the window and center the case Lower the window behind the top mounting rail Pull the bottom of the case forward so that the bottom mounting rail is tight against th...

Page 12: ...weak or if the weight of the air conditioner falls between the studs in the wall F Extend the left and right accordion panels to the vertical window sashes Drill pilot holes and attach the top and bot...

Page 13: ...bottom corners and pull it forward Unhook it from its top hinges and set it aside F Using the tab pull up slightly on the filter to release it and pull it down and out 8 INSTALL THE AIR CONDITIONER IN...

Page 14: ...GH HEAT Filters and circulates room air with the fan running continuously on high speed Also heats while the compressor or electric heater is running Select this setting for maximum air circulation an...

Page 15: ...ature Control to cooler setting For heating turn Temperature Control to warmer setting NOISY UNIT Loose front on mounting assembly Weak building construction Water hitting fan blade Unit oversized for...

Page 16: ...quent failure of unit voids warranty Warranty details are contained in warranty certificate enclosed with unit Keep accurate records of service calls including what was done servicer s name and date o...

Page 17: ...m side to side Use wood shims between sides of case and finished opening especially where case is secured to opening to prevent warping or distorting Check installed case for distortion using carpente...

Page 18: ...se is properly positioned in opening use wood shims to fill any gaps between case and finished opening especially in area where case will be secured to opening Take care not to warp or distort case wh...

Page 19: ...e Highside 340 P S I Cooling AMPS 9 7 8 9 Cooling Watts 1955 2000 Cooling EER 9 0 Heating AMPS 8 8 8 3 Heating Watts 1790 1850 Heating EER 9 2 Electric Heat AMPS 15 6 16 Electric Heat Watts 3600 Air F...

Page 20: ...ect accident incorrect power line voltage fire flood or other Acts of God or normal wear and tear Warranty service must be performed by a qualified HVAC contractor Soleus maintains a centralized servi...

Reviews: