background image

 11 

CONTINUOUS MODE—GARDEN HOSE INSTALLATION AND SETUP 

Water can be automatically emptied by attaching a hose to the continuous drainage port on the back of the dehumidifier. This will 
allow the unit to run continuously (depending on the selected humidity level) without having to empty the water bucket. To drain, 
simply attach a standard garden hose (not included). The thread standard for garden hoses in the US and its territories is known as 
GHT or "garden hose thread" which has an outer diameter of 1 1/16 inches (1.0625 inches or 27.0 mm) and a pitch of 11.5 TPI.  

Place dehumidifier on a level surface.

Unscrew the cap on the back of the unit to access the garden hose nozzle

Thread a garden hose (not supplied) onto the accessible nozzle, lead to a floor drain and cut to length.

Make sure that there are no kinks or knots in the garden hose. (See Picture Below)

Turn on the unit and press the MODE button until set to CONTINUOUS.

Garden Hose Installation Reference Guide 

IMPORTANT NOTES: 

Placing the dehumidifier on an uneven surface or improper hose installation may result in water filling up the bucket and causing the 
unit to shut off. Empty bucket if shut-off occurs, then check dehumidifier location and hose for proper setup. The bucket must be in 
place and securely seated for the dehumidifier to operate. 

For more details, please scan below QR code for operation instruction video : 

Summary of Contents for iCongo R-DS1-30-01

Page 1: ...Model No R DS1 30 01 R DS1 45E 101 R DS1 70E 101 3058080 30 Pints 45 Pints 70 Pints REFURBISHED Portable Dehumidifier Operating Instructions V160328...

Page 2: ...r time this humidity level will become more and more stable Due to the stable humidity level in the area the dehumidifier will need to remove less and less moisture over time Please do not be concerne...

Page 3: ...midi fying power or quiet operation Bucket full indicator and audible alarm signals as soon as the bucket is full and ready to be emptied Ultra quiet operation allows for use almost anywhere Perfect f...

Page 4: ...is owner s manual carefully Store this manual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this...

Page 5: ...ESENTED HEREWITHIN PACKAGE CONTENTS 1 Portable Dehumidifier 1 Operating Instructions 4 Casters 1 Bucket Handle Model Number DS1 30 01 DS1 45E 101 DS1 70E 101 Dehumidifying Capacity 30 Pints per day 45...

Page 6: ...and forcibly insert the casters Make sure the ring around the caster is flush against the bottom of the dehumidifier CONTROL PANEL DIGITAL DISPLAY POWER BUTTON INCREASE DECREASE ROOM HUMIDITY LEVEL TI...

Page 7: ...he different fan speeds High Medium and Low The fan speed can be visually distinguished by the fan speed indicators on the control panel 5 Timer Auto On To program the unit to automatically turn on pr...

Page 8: ...mildew and bacteria Use a mild detergent to clean the bucket Once clean completely dry the bucket and place it back inside the dehumidifier NOTE When the bucket is full or removed from the machine the...

Page 9: ...WITHOUT THE INCLUDED FILTER 8 MyHome Modes Preset humidity level settings allow the user to easily move the dehumidifier room to room and select the corresponding mode for the location in which the d...

Page 10: ...which may reduce performance Use the dehumidifier in cooking laundry bathing and dishwashing areas that have excessive moisture NOTE Place the dehumidifier away from a clothes dryer Use the dehumidif...

Page 11: ...el surface Unscrew the cap on the back of the unit to access the garden hose nozzle Thread a garden hose not supplied onto the accessible nozzle lead to a floor drain and cut to length Make sure that...

Page 12: ...he Unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel End of Season Storage Transporting the...

Page 13: ...tton to lower the percent humid ity desired in the room or set the dehumidifier to CO for maximum dehumidification Doors and windows may not be closed tightly Check that all doors windows and other op...

Page 14: ...ff when either condi tion occurs Change to a lower setting or empty the water bucket and replace properly Bucket is not in the proper position The bucket must be in place and securely seated for the d...

Page 15: ...lf Diagnosing Code Description Resolution E1 Compressor Overheat Protec tion Please call Soleus Customer Service at 877 976 5387 E2 Condenser Overheat Protection Please call Soleus Customer Service at...

Reviews: