10,000 BTU Portable Air Conditioner
Operating Instructions
Model No. GM-PAC-10E2
Page 1: ...10 000 BTU Portable Air Conditioner Operating Instructions Model No GM PAC 10E2 ...
Page 2: ... manual carefully Store this manual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clearance space around this unit Do not block or cover air inlet or outlet grilles 4 The unit must be connected to a correctly grounded...
Page 3: ...they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet 2 Press TEST Button circuit should trip cutting power to the air conditioner 3 Press RESET button for use If a test is performed and the...
Page 4: ...A 1 5V INCLUDE Window ExhaustAdapter B SUGGESTED TOOLS FOR WINDOW PANEL INSTALLATION 1 Screwdriver medium size Phillips 2 Tape measure or ruler 3 Knife or scissors 4 Saw In the event that the window panel needs to be cut down in size because the window is too narrow for direct installation Manual Remove control Drain hose Hose Clamp hook 2 Power cord 2 4 ...
Page 5: ...t 6 Vertical louvers 7 Horizontal louvers 8 Wheel 9 Air inlet 10 Grille 11 Air outlet 12 Air inlet 13 Power cord hook 14 Power cord 15 Windowexhaustadapter A 16 Exhaust hose 17 Window exhaust adapter 18 Window exhaust adapter 19 Remove control STRUCTURE Front Rear 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 B C 5 ...
Page 6: ...aust Hose 1 Window Exhaust Adapter A 1 Window Exhaust Adapter B 1 Window Exhaust Adapter C 1 Remote Control AAA Batteries 2 batteries Window Kit 3 Sliding Panels 1 single hose panel 2 extension panels Drain Hose Assembly drain pipe hose clamp hose clip rubber plug screw Owner s Manual Model Number Power Supply Ph V Hz 1 115 60Hz Dehumidifying Capacity Pints Day 60 Rated Cooling Capacity BTU h 10 0...
Page 7: ... Attach the hooks to the back of air conditioner with the screws hoook screw Wind the power cord round the power cord hooks 7 INSTALLATION OF THE POWER CORD HOOK ...
Page 8: ...se a suitable location near a grounded electrical outlet and suitable window or door Remove packaging and locate components x Extend both ends of the exhaust hose approximately 6 inches x Screw the window kit adapter onto one end of the exhaust hose clockwise Screw the hose adapter onto the other end of the exhaust hose clockwise x Mount the exhaust hose onto the back of the unit by locking the ho...
Page 9: ...t as flat as possible The less angles and bends in the hose the better the unit will perform If bending or an angle is necessary use single 90 angles like the pictures above Multiple bends will decrease performance and efficiency This installation is OK The is a poor installation 22 26 ...
Page 10: ... guides to direct air where cooling or fanning is needed most Hold the louver and adjust the air flow direction as show in the right diagram 5 Water Full When COOL or DRY is running condensate will drain to water tank When water tank is filled buzzer will sound 8 times LED screen show error code H8 In this case reference page 8 to drain out water intank Press the button once to manually turn the u...
Page 11: ...e units signal receiver window and pres s the des ired button A beep will sound when the unit re ceives the signal blocks the signal receiver window CAUTION its operation If necessary close the curtains to block out the sunlight VCRs or other equipment used in the same room remote control from moisture and shock which can discolor or damage it 11 ...
Page 12: ...n to cycle through low medium and high fan speeds The small fan icons will light up depending on which speed is selected The more fan icons light up the higher the speed The fan icons are located on the LCD display next to the SPEED label 4 Temperature Setting When the unit is in Air Conditioner mode you can select your desired temperature Press the TEMP SELECT buttons or to select your desired te...
Page 13: ... button to cancel the timer 6 Sleep Mode Press the SLEEP mode button to engage SLEEP mode Sleep mode automatically reduces the set temperature by 2 F after one hour and 4 F after two hours This feature limits compressor usage and enhances energy savings while you are sleeping 7 Auto Mode When AUTO mode is selected the air conditioner will automatically choose the operating mode base on the current...
Page 14: ...tions below 1 Remove the pre installed Drain Cap from the unit See Below 2 Attach the Clamp with the provided Screw See Below 3 Attach the Drain Hose to the Drain Port using the Drain Hose Clip Insert the Drain Plug into the free end of the Drain Hose and guide the Drain Hose through the Clamp Once finished the unit can be easily drained by removing the drain plug and guiding the drain hose into a...
Page 15: ...ried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the unit 1 Empty any excess wate...
Page 16: ...ET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold air is escaping The Evaporator is frozen x Make sure there are no curtains blinds or furniture blo...
Page 17: ...ug for 10 minutes and then turn on the unit If E5 is still dis played contact customer service TROUBLESHOOTING CONT The LCD Display is showing H8 The backup water tank is full x Drain the water tank x If the H8 I still displayed after the water tank has been emptied con tact customer service 17 ...
Page 18: ...r appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENT...