  13 SEER Mini Split Air Conditioner

with Heat Pump and Back up Electric Heat Strip

KFTHP-12-ID/KFTHP-12-OD
KFTHP-18-ID/KFTHP-18-OD
KFTHP-24-ID/KFTHP-24-OD

LI

D

S E

T

RT

E

E

T

K

N

I

 CM

 US

 C

3119233

Summary of Contents for 3119233

Page 1: ...13 SEER Mini Split Air Conditioner with Heat Pump and Back up Electric Heat Strip KFTHP 12 ID KFTHP 12 OD KFTHP 18 ID KFTHP 18 OD KFTHP 24 ID KFTHP 24 OD LI D S E T RT E E T K N I CM US C 3119233 ...

Page 2: ...nufacturer If Auto restart function is not needed follow the steps below to cancel this function 1 Make sure the power is 2 Keep pressing the Emergency button for more than 10 seconds until four short beeps are heard Then Auto restart function is disabled To activate the Auto restart function repeat above procedure until three short beeps are heard air conditioner air conditioner turned off at rem...

Page 3: ...G AUTO HI DRY FAN HEAT COOL FEEL SLEEP TIMER ON OFF Use correct power supply in accordance with the rating plate requirement Otherwise serious faults or hazard t such as a fire could occur If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Remove the power source plug from a socket Do not use extension c...

Page 4: ...Intake Air Intake Air Outlet Louver Vertical Adjustment Louver Horizontal Adjustment Electrostatic Filter optional Charcoal Filter optional Air Filter Remote Control Front Panel Emergency Panel Display Panel Note Condensate water drains at COOLING or DRY operation Identification of Parts Indoor Unit Outdoor Unit 1 1 Drain Hose Connection Cord Pipes and Power Air Outlet ...

Page 5: ...upply is on Power Indicator It lights up when power supply is on Signal Receives Receive signal from the remote control TIMER RUN SLEEP POWER Used to control the unit when the remote control is out of work This is suitable for C D N R L M Y and Z series way of operation ON OFF Used to control the unit when the remote controller is out of work This is suitable for E F G H J K Q Z BD BE BF BG BH and...

Page 6: ...t TIMER operation Signal Transmitting Window Transmits signals to the system Setting Display 1 2 3 4 8 5 6 7 13 10 14 11 12 9 13 SUPER button optional 10 ECO button optional 14 HEALTHY button optional 11 DISPLAY button optional 12 ANTI MILDEW button optional 9 3D button optional Used to start and stop SUPER operation Used to start and stop ECONOMY operation This function is invalid in SUPER mode U...

Page 7: ...he remote control mades a short Auto Test all the symbols can be displayed are shown on the screen and keep 2 seconds then the symbol will flash from For cooling only air con please press any button when the cooling symbol is flashing the the remote controller has been set as cooling only For cooling and heating please press any button when the heating symbol is flashing then the remote control ha...

Page 8: ...itioner aim the remote control to the signal receptor The remote control will operate the air conditioner at a distance of up to 10 feet when pointing at signal receptor of indoor unit Remote control holder Signal receptor Remote Control Remote Control Please slide and remove the cover Exchange the batteries Install the cover 1 2 3 Attention to the and marks Slide the cover upwardly in the directi...

Page 9: ...sible with the button or the button Press the MODE select button Move the MODE to the FEEL position 1 2 Operates by selecting automatically the operation mode HEAT DRY FAN COOL depending on the room temperature during staring Press the button or the button When the button is pushed the temperature will increase 1 f When the button is pushed the temperature will reduce 1 f After temperature will in...

Page 10: ...SLEEP operation is switched from Normal SLEEP to SLEEP alternatively Having This function is invalid in fan and dehumidify mode This function is invalid in SUPER mode too Switches OFF the appliance automatically after 10 hours in Normal SLEEP mode Comfortable Used to set or cancel sleep operation Normal SLEEP only 2 While the unit is running Switches OFF the appliance automatically after 8 hours S...

Page 11: ...dusty environment Stop the appliance and remove the air filter 1 Open the front panel 2 Press the handle of the filter gently from the front 3 Grasp the handle and slide out the filter soft cloth to clean it Use a dry and Grasp position a and pull outward to remove the front panel a a b b Maintenance 1 1 At the end of the season Set temperature to for about half a day and perform the Cooling opera...

Page 12: ...t is discharged 2 5 minutes later In HEATING operation the appliance will defrost de ice automatically to raise efficiency This procedure usually lasts 2 10 minutes During defrosting fans stop operation After defrosting completes it returns to HEATING mode automatically Protection Features of protector Inspection After using for long time the air conditioner should be inspected on the following it...

Page 13: ...isconnect from the power supply and connect back 2 3 seconds later Changing mode during operation 3 minutes will delay This odor may come from another source such as furniture cigarette etc which is sucked in the unit and blows out with the air Caused by the flow of refrigerant in the air conditioner not a problem Defrosting sound in heating mode The sound may be generated by the expansion or cont...

Page 14: ...er 6 should be over 6 feet Should be over 12 Installation must be performed in accordance with the national wiring standards by authorized personnel only Above figure is only a simple presentation of the unit it may not match the external appearance of the unit you purchased Installation Instructions Installation Diagram 1 1 NOTE NOTE Very Important Installation must done by a registered qualified...

Page 15: ...nit Where there is no obstacle near the air outlet and air can be easily blown to every corner Where piping and wall hole can be easily arranged Keep the required space from the unit to the ceiling and wall according to the wiring diagram Where the air filter can be easily removed Keep the unit and remote control or more apart from television radio etc Keep as far as possible away from fluorescent...

Page 16: ... sleeve through the wall hole to keep the wall tidy and clean Drill a hole on the wall The hole should tilt a little downward toward outside Decide the position of hole for piping according to the location of mounting plate 2 Drill a Hole for Piping Keep the mounting plate horizontally with a horizontal ruler or dropping line Drill holes of in depth on the wall for fixing the plate 1 Insert the pl...

Page 17: ...re drain hose drain hose large pipe large pipe small pipe small pipe 1 1 NOTE NOTE The temperature of refrigerant circuit will be high please keep the interconnection able away from the copper tube c Refrigerant Line Connection Torque Table Flare Nut Tightening Torque 1 4 3 8 1 4 1 2 1 2 3 4 7 8 1 1 8 25 Ft LBs 350 Kg Cm 40 Ft LBs 560 Kg Cm 60 Ft LBs 840 Kg Cm 110 Ft LBs 1540 Kg Cm Tighten flares ...

Page 18: ...llation Instructions Caution 1 Never fail to have an individual power circuit specifically for the air conditioner As for the method of wiring refer to the circuit diagram posted on the inside of the access door 2 Comfirm that the cable thickness is as specified in the power source specification See the cable specification table below 3 Check the wires and make sure that they are all tightly faste...

Page 19: ...t the condensate water Just install the drain port and rubber washer to the chassis of the outdoor unit then connect a drain hose to the port as the right figure shown The air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the compressor After connecting the indoor and outdoor units evacuate air and moisture from refrigerant cycle using a vacuum pump as sho...

Page 20: ...ke off the cover for Interconnection cable of outdoor unit Diagram for installation of Interconnection cable please see the pasted diagram instruction on the body first Installation Instructions 1 1 Interconnection Cable Circuit Diagram Note Some models are designed without the conneting terminal in indoor unit please subject to the connetion diagram of the product Cooling Heating Connetting indoo...

Page 21: ...in case of need If not possible connect appliance to a double pole switching device with contact separation of at least placed in an accessible position even after installation 1 1 1 NOTE NOTE Test Running Connect to the power source check if the function selection keys on the remote controller are working properly Check if the room temperature adjustments and timer settings are working properly C...

Page 22: ...Model KFTHP 12 OD Model KFTHP 12 ID ...

Page 23: ...Model KFTHP 18 ID Model KFTHP 18 OD ...

Page 24: ...Model KFTHP 24 ID Model KFTHP 24 OD ...

Page 25: ......

Page 26: ......