1.

 

Before You Begin 

 

a.

 

Precautions 

Solectek shall not be responsible for any operation of this product which is in violation of local law, creates interference 
harmful to other local devices, or results in a malfunction of this product caused by outside interference. 
 
This device must be professionally installed and used in strict accordance with the manufacturer's instructions. However, 
there is no guarantee that interference to radio communications will not occur in a particular commercial installation. In case 
the device does cause harmful interference with an authorized radio service, the user/ operator shall promptly stop operating 
the device until harmful interference has been limited. Solectek Corporation is not responsible for any radio or television 
interference caused by unauthorized modification of this device or the substitution or attachment of connecting cables and 
equipment other than specified by Solectek Corporation. The correction of interference caused by such unauthorized 
modification, substitution, or attachment will be the responsibility of the user. 
 
Solectek shall not be liable for damages associated with the installation and use of this product, including but not limited to 
personal or property damage, business losses or infringement of local or national laws. 

 

b.

 

Package contents 

Included with the SkyWay-MAX Subscriber Station Unit is the following: 
 

 

Subscriber Station Unit Chassis  

 

100-240 VAC Power over Ethernet module 

 

Power Cord (bulked packed separately) 

 

Installation Kit, including: 

o

 

Mounting foot 

o

 

Mounting knuckle 

o

 

bolts, 2 

o

 

flat washers, 4 

o

 

split washers, 4 

o

 

inside tooth washers, 2 

o

 

nuts, 2 

o

 

screw-band clamps, 2 

 

Verify that all included items are present before attempting to install the unit. 

 

2.

 

Mounting Procedure 

 

a.

 

Mounting Location - Considerations 

The integrated panel antenna on the Subscriber Station (SS) is directional, so the unit must be aimed 
directly towards the Base Station (BSU) signal. Identify a location on a wall or pole (preferably 
outdoors) that faces the BSU.   The SS is housed within a weatherized, outdoor-grade plastic enclosure; 
however, it should be mounted in a location where it will not be subjected to gutter overflow or other 
excessive moisture. Likewise, the SS should not be mounted near electric conduit or other source of 
electromagnetic interference (EMI), such as a ballast for a fluorescent light fixture. 
For best performance, however, orient the unit so that the signal path to the BSU is as free from 
obstructions as possible. 

Summary of Contents for SkyWay-MAX

Page 1: ... damages associated with the installation and use of this product including but not limited to personal or property damage business losses or infringement of local or national laws b Package contents Included with the SkyWay MAX Subscriber Station Unit is the following Subscriber Station Unit Chassis 100 240 VAC Power over Ethernet module Power Cord bulked packed separately Installation Kit includ...

Page 2: ...mended A Mounting the SS to a wall A Attach the pivot knuckle to unit 1 Place the inside tooth washer on the molded flange 2 Thread the bolt through the pivot knuckle and attach washers and nut NOTE Do not overtighten the nut it should be snug enough to keep the unit steady but allow the position to be adjusted B Attach the bracket to the wall 1 Mount the bracket with the slots oriented horizontal...

Page 3: ...ottom and do not overtighten the nut it should be snug enough to keep the unit steady but allow the position to be adjusted B Mounting the SS to a mast 1 Attach the bracket to a vertical mast i Orient the slots to be parallel with the pole ii Thread the screw bands through the slots around the pole and back through the slots ...

Page 4: ...ition to be adjusted c Connecting the unit to power and customer network Using the supplied power cord connect the power adapter to AC power WARNING The power adapter is not rated for outdoor use Connect a shielded twisted pair STP Category 5 or better cable to the connector marked OUT on the adapter This cable will deliver both power and network access to the unit it should be long enough to reac...

Page 5: ...3 SIGNAL displays the alignment index or received signal strength depending on mode See Signal LEDs below 4 NET Illuminates when an Ethernet link has been established Flashes during Ethernet network activity 5 PWR Illuminates when the unit is powered Note the unit will always be on when connected to a power source e Signal LEDs The SS Signal LEDs operate in two different modes Alignment Mode and R...

Page 6: ...mber of LEDs on RSSI value 1 81 dBm 2 77 dBm 3 69 dBm 4 53 dBm 5 53 dBm The Alignment mode can be restarted at any time by removing the STP cable waiting five seconds and then connecting the cable back to the RJ45 jack Once Antenna Alignment is complete secure all fasteners insert the STP cable into the cable guide and replace the weather cap 3 Pre configuration To simplify initial BSU and SS inst...

Page 7: ...ironment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Warning Changes or...

Reviews: