Troubleshooting
Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · [email protected]
35
Marine diesel engines. Operator’s manual
Relays
The relays of the electrical installation are located inside the electrical protective box where
it is shown in the image.
The earth isolated motors have bipolar relays, in the images can see the position.
Maintenance task. Incandescent glow plug inspection
1.
Loosen nuts, and then remove connection plate and glow plug.
2.
If the glow plug glows red when the positive (+) wire is connected to the portion A with the
portion B grounded, the plug can be used.
Maintenance task. Starter inspection
STARTER:
1.
Check if there is any impurity in pinion teeth.
2.
Make sure that the pinion shaft turns freely when turned in the
direction of driving (clockwise) and it is locked when turned in the
opposite direction. If not, replace the overrunning clutch.
Maintenance task. Alternator belt tension inspection
Push the belt inward with thumb pressure exerted midway between the
pulleys, as shown, to check the belt tension (deflection). If the tension is
Rated Voltage - Current
12 V
9,7
–
10,5 A