Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · [email protected]
38
Marine Diesel gensets. Operator’s Manual.
Systems and scheduled
maintenance
Battery
The minimum recommended capacity is from 55-120 Ah. However, this value serves as a
general reference since it relates to the maximum intensity it can offer for starting the generator set.
The connection of the battery for a standard engine:
•
Positive battery is connected to the starter.
•
Negative battery is connected to the relay support.
The connection of the battery for an earth isolated engine.
•
Positive battery is connected to the starter.
•
Negative battery is connected to the bipolar relay.
Circuit protection
AC Breaker interrupts the genset output in the event of an overload or short circuit. The
nominal current is indicated in the following table:
Maintenance task. Incandescent glow plug inspection
1.
Loosen nuts, and then remove connection plate and
glow plug.
2.
If the glow plug glows red when the positive (+) wire is
connected to the portion A with the portion B
grounded, the plug can be used.
Genset model
Battery capacity (Ah)
12V
24V
29 GSC / 32 GSAC /35 GTC / 40 GTAC / 45 GTC / 54
GTAC / 50 GTC / 60 GTAC /
92
-
68 GTC / 84 GTAC
120
-
Model
Current (A)
29 GSC /32 GSAC
125
35 GTC / 40 GTAC
80 (Delta) / 50 (Star)
45 GTC / 54 GTAC
125 (Delta) / 63 (Star)
50 GTC / 60 GTAC
125 (Delta) / 63 (Star)
68 GTC / 84 GTAC
160 (Delta) / 100 (Star)
Rated voltage - Current 12 V
9,7-10,5 A
Glowplug
Nut
Connection board