Troubleshooting
GENSET FAILURE
SYSTEM
PROBABLE CAUSES
RECOMMENDED ACTIONS
Power cable fuse (red).
Replace the fuse in the installation. If fuse blows again, check
electrical system for overloads or short circuits.
Discharged or empty battery.
Charge the battery or replace it with a new one.
Loose or corroded battery connections.
Check the battery connections are correct, clean and tight.
Faulty start/preheating relay.
Check and replace the preheating/start relay if necessary.
Faulty starter motor
Check starter motor and replace it if necessary.
Control panel start signal
Check the start signal from the controller (pink wire).
Faulty stop solenoid (ETR).
Check stop solenoid and replace it if necessary.
GENERAL
Low compression pressure.
Check the compression of each cylinder.
LUBRICATION SYSTEM
Oil viscosity too high.
Check oil viscosity (according to Technical Specifications).
Faulty or clogged fuel pump.
Check the pump by verifying the fuel inlet and outlet of the
pump. Replace it with a new one if necessary.
Clogged fuel pipes
Check fuel pipes.
Clogged fuel filter
Replace fuel filter.
Faulty injection pump
Contact an Official Solé Diesel Service.
Air in fuel system
Bleed fuel system.
Dirty or faulty fuel injectors
Clean, test and/or replace fuel injector which is not operating
properly.
Fuel injection timing malfunction
Adjust fuel injection timing
Empty fuel tank or closed fuel valve.
Add fuel and place fuel valve in open position.
Dirty or clogged fuel tank.
Clean tank with proper products.
INLET AND EXHAUST
SYSTEM
Dirty or clogged air filter.
Replace the air filter element.
ELECTRICAL SYSTEM
(CC)
FUEL SYSTEM
MANUAL START
FAILURE