TECHNICAL APPENDICES
64
Manual del Operador Grupos Electrógenos Marinos
Revisión 2. 10/2017
Function control of the configured warning lamps
With the ECU activation (key switch (pin 15)), the warning lamp is also switched on for the
duration of the self-diagnostic (2 s).
Diagnostic button and Fault indicator lamp
With the diagnostic button there is the possibility of reading out the existing faults as blink
codes and to delete the fault memory 1. The Diagnostic button and the fault indicator lamp are
situated in the ECU cabinet.
Reading out a current fault memory blink codes
The fault indicator lamp shows a fault, e.g., it flashes or lights continuously. The Diagnostic
button is depressed for a time period of 1 s to 3 s. The regulator recognizes the request for a read
out and starts to display the faults. The read-out of the blink code is only possible after extinguishing
of fault indicator lamp or after the initialization phase of the operating program.
This means that the fault indicator lamp can also show continuous lighting after switching
on if a fault has been recognized already after switching. The ECU only shows active faults as blink
codes.