TROUBLESHOOTING
39
Manual del Operador Grupos Electrógenos Marinos
Revisión 2. 10/2017
GENSET FAILURE
PROBABLE CAUSES
RECOMMENDED ACTIONS
SECTION
FAILURE TO CRANK
SCO 10 PANEL
OFF mode
Move to MAN mode.
7.1
Fuse (red wire) burned out
Replace the controller fuse. If the fuse blows
again, troubleshoot the controller.
5.8
ELECTRICAL SYSTEM
(DC)
Battery discharged or dead
Recharge or replace the battery.
5.8
Battery connections loose, corroded or
incorrect
Verify that the battery connections are
correct, clean and tight.
5.8
Faulty cranking relay/stop solenoid
Check the cranking relay and the stop
solenoid. If necessary, replace.
-
Faulty starter motor
Replace if it is inoperative.
5.8
FAILURE TO START
PANEL SVT
Key switch
Check the pin connections and check that they
have voltage.
-
Electronic board
Check that goes voltage electronic board to
micro relay.
-
ELECTRICAL SYSTEM
GENSET
Blown fuse
Replace the controller fuse. If the fuse blows
again, troubleshoot the controller.
6.8
Battery discharged or dead
Recharge or replace the battery.
6.8
Battery connections loose, corroded or incorrect
Verify that the battery connections are correct,
clean and tight.
6.8
Faulty cranking relay/stop solenoid
Check the cranking relay and the stop solenoid. If
necessary, replace.
-
Faulty starter motor
Replace if it is inoperative.
6.8
GENERAL
Compression weak
Check the compression.
6.3
LUBRICATION SYSTEM
Oil viscosity too high
Check the oil viscosity (according to technical
specifications).
6.4
FUEL SYSTEM
Fuel pump faulty or clogged
Check fuel pump inlet.
6.5
Fuel lines obstructed
Check fuel lines.
6.5
Fuel filter clogged
Replace fuel filter.
6.5
Faulty injection pump
Contact with our dealer
-
Air in fuel system
Bleed fuel system.
6.5
Summary of Contents for 100 GTA