Solark CWS-09KDC Operation Manual Download Page 1

 

 

SPLIT TYPE WALL MOUNTED HEAT PUMP 

FULL DC INVERTER AIR CONDITIONER 

 
 
 
 

 

 

OPERATION MANUAL 

 

 

 

 

 

CWS-09KDC 
CWS-12KDC 
CWS-18KDC 
CWS-24KDC 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  To  guarantee  operating  the  unit  correctly  and  safely,  please  read  this  manual 

carefully before using. Keep a suitable storage for reference. 

  Please  consign  to  professionals  to  install  the  air  conditioner  to  guarantee  the 

safety and function. 

  The unit must be earthed reliably. 

 

Summary of Contents for CWS-09KDC

Page 1: ...12KDC CWS 18KDC CWS 24KDC To guarantee operating the unit correctly and safely please read this manual carefully before using Keep a suitable storage for reference Please consign to professionals to...

Page 2: ...2...

Page 3: ...ION METHOD 7 a Auxiliary controller and LED display b Remote controller c Operation method 5 OPERATION GUIDE 13 6 MAINTENANCE 14 7 TROUBLE CHECKING 15 8 INSTALLATION 17 a Requirement of indoor unit b...

Page 4: ...n design like the super quiet operation and the computerized control system Only proper installation and operation can assure the capability of the air conditioner The air conditioner should be set up...

Page 5: ...tenance department NOTICE 1 The quality of the electric outlet must be reliable otherwise it will cause fire or other accident 2 Ensure proper connection of drain pipe Otherwise it may cause water lea...

Page 6: ...6 3 STRUCTURE...

Page 7: ...the remote controller Please set this position as normal operation LED Display Indicating of the power It will indicate when the power is on There is something wrong with the main power source transfo...

Page 8: ...t the remote controller at the receiver window 2 Be sure that there is no ay barrier between the receiver window and the remote controller Valid distance is less than 7m 3 Do not leave any liquid flow...

Page 9: ...t temperature 4 Press FAN to select the fan speed 5 Press VANE to select the direction and state of the airflow Note Select heating the set temperature should be higher than indoor temperature otherwi...

Page 10: ...ress DRY to select the cooling mode 3 Press VAN to select the direction and state of the airflow Note During drying the air conditioner operates on and off the on off time is automatically controlled...

Page 11: ...timing mode and indicates timing time when in timing mode 8 Louver function 1 The direction of the vertical airflow is adjusted by the horizontal louvers Press VANE to adjust At certain position of l...

Page 12: ...lly according to indoor temperature 3 Under auto operation the unit is out of control of the remote controller Room temperature Mode Set temperature 28 Cooling 28 24 28 Pause 23 Heating 23 10 Test mod...

Page 13: ...ing In order to enhance cooling efficiency you should close the door window and window curtain avoid solarization directly Please regularly clean the air strainer if it is blocked the heating cooling...

Page 14: ...ty the position rusted should be painted to prevent expanding B Please check the unit before use after a long time period of no operation Check the reliability of earthing Check if any obstacle cloggi...

Page 15: ...plug is unplugged Check if circuit breaker is open Check if voltage is normal Check if the temperature setting is correct Check if timed on function is properly set Performance of cooling and heating...

Page 16: ...g and contact the agent There is harsh noise when the air conditioner working The fuse and breaker often act The power cord and plug are very hot The indoor unit leaks water The surface of the unit be...

Page 17: ...ugh space for convenient maintenance The indoor unit should be set up higher than the eye level b Requirement of outdoor unit The outdoor unit should be installed on a rigid base It is necessary to le...

Page 18: ...18 INSTALLATION c Installation step...

Page 19: ...unit and the direction of pipes Please leave enough place for installation 2 The wall mounted plate should be fixed horizontally and vertically or the water will drop on the floor 3 The wall mounted p...

Page 20: ...ts After turning the nuts off from the connecting pipes ends the pipes should be connected immediately to prevent dust and water entering the system The tie in nut can not be fixed excess tight or loo...

Page 21: ...he connecting pipes power wire and drain hose together with binding belt The drain hose must be set below 5 Hand the indoor unit to the wall mounted plate move the unit to ensue if it is fixed press t...

Page 22: ...panners should be used when connecting the indoor unit connecting pipes especially for the liquid pipe If fixed excess fasten the pipe will be distorted and damaged 3 Length of single connecting pipe...

Page 23: ...for 2 5mm and move it slowly When the checker gives a warning it need check again If the checker does not warn it shows the leakage doesn t occur If the checker gives a warning continuously it shows t...

Page 24: ...GRN should be connected first then the current carrying wires BRN When disconnecting the current carrying wires should be disconnected first then the earth wires 4 The ends of wires must be inserted...

Page 25: ...ttle 5 Open just half the knob valve of the refrigerant pot 6 After 3 seconds screw the tie in nut of the refrigerant charging pipe 7 Read the number of the pincers ammeter or electron balance Refrige...

Page 26: ...plate 2 Install drain hole prepare it yourself 2 If the drain hose fitting if used the outdoor unit should be installed in a bracket more than 3 cm 12 Finishing 1 Pack up the connecting wires and pipe...

Page 27: ...15 DB outside 6 DB 2 Horizontal louver is set in initial position indoor fan speed is max 2 Max conditions Cooling inside 32 DB outside 35 DB 23 DB outside 24 DB Heating inside 27 DB outside 24 DB DB...

Page 28: ...28...