SOLARFOCUS pellettop 35/45 Operation Manual Download Page 1

Operation manual for the system operator

Read carefully before operating.

DR-6011-EN / v29-201904

Pellet boiler

pellet

top

Summary of Contents for pellettop 35/45

Page 1: ...Operation manual for the system operator Read carefully before operating DR 6011 EN v29 201904 Pellet boiler pellettop...

Page 2: ...ontrol to the internet 27 12 3 Register on the web server 27 12 4 Install app register user 28 12 5 Add system 28 12 6 Use of the mySOLARFOCUS app 29 12 7 Approve additional users 29 13 Weatherman fun...

Page 3: ...r SOLARFOCUS service partner Keep unauthorized persons and children away Danger of burns due to hot lines and hot com ponents risk of injury from mechanically moving parts Keep unauthorised persons aw...

Page 4: ...any SOLARFOCUSwill determine whe ther such work requires a repair or whether the parts are to be replaced free of charge Expiry of maintenance warranty and gua rantee services The maintenance warranty...

Page 5: ...r The ash produced is collected in an ash box which must be emptied at regular intervals 4 4 Spare parts For repairs use only original spare parts or parts appro ved by the manufacturer e g standard p...

Page 6: ...STL must be manually released again by unscrewing the black sealing cap 1 and pres sing the button as soon as the boiler temperature falls below 60 C If the safety overtemperature reset trips this is...

Page 7: ...ne for conveying the pellets 6 Induced draft fan 7 Flue gas pipe 8 Intermediate pellet store 9 Heat exchanger cleaning 10 Screw pellet feeder and rotary valve 11 Ignition device glow pencil 12 Combust...

Page 8: ...Please note the following recommendations from the EU Energy Efficiency Directive Use of a buffer tank As the most complete combustion of wood pellets is possible only when the boiler is in normal op...

Page 9: ...00 13 3000 16 Fuel Fuel Wood pellets acc to EN17225 2 ENplus A1 Capacity of intermediate pellet store l 95 95 250 250 Flue gas side Flue gas pipe diameter cm 15 15 20 20 Height centre of flue gas pipe...

Page 10: ...use a room sealed independent draught limiter 6 Flue gas values in mg m3 are based on 13 O2 of the volume flow 4 12 Dimensions pellettop 35 45 ash container may be mounted on the right or left pellett...

Page 11: ...s to the Selection menu 11 5 2 Boiler operating mode 1 Chimney sweep function This function is used to perform the emission mea surements prescribed by law Perform emissions measurement 36 2 STOP The...

Page 12: ...put test boiler CAUTION only to be under taken by qualified personnel 8 Qualified personnel menu 15 2 Button is only visible if a message is active 5 4 1 Required boiler values Fig 2 9 Required boiler...

Page 13: ...he suction turbine and the tank is filled once i e current level and release times are not considered Prerequisite the boiler must have the status Switched off or Standby Manual filling 4 Pressing the...

Page 14: ...ck icon 1 in the screens User lock screen Fig 2 13 Enter the password 2 To define a new password maximum 20 characters Password 3 The currently valid password is displayed User lock 4 Off The user loc...

Page 15: ...by the customer i e not included in the commissioning service and sup port activities The following points are helpful for setting up a PC router to control the VNC server which requires know ledge of...

Page 16: ...e To create a connection with the control unit a port diversion is required from the external port of the router 1 to the IP address and to VNC port 5900 of the control unit 1 Port 5950 is recommended...

Page 17: ...faults Status e Mail Set time at which the status e mail is sent The automatically generated content of the sta tus e mail is Current status of the heating system Fault present and which Alarm select...

Page 18: ...gs Button is only visible when the Room effect parameter is set to On or Sliding this can be found in the Specialist per sonnel system parameters 3 General settings 19 4 Heating curve 19 6 1 1 Heating...

Page 19: ...on Buffer difference The burner starts when the tank temperature top falls below the required flow temperature minus the buffer difference Example Current flow required temperature 50 C Buffer differ...

Page 20: ...the following illustration Flow temperature at outside temperature of 15 C 45 C Flow temperature at outside temperature of 15 C 22 C Current external temperature 5 C In the heating circuit operating m...

Page 21: ...value at 7 too hot Reduce temperature value at 7 5 C to 5 C too cold Increase temperature value at 11 too hot Reduce temperature value at 11 5 C to 15 C too cold Increase temperature value at 8 too ho...

Page 22: ...C and the DHW tank temperature goes to 10 C Always on The DHW tank charge pump is switched on permanently The pump is controlled taking the para meters Required temperature 1 Minimal temperature and H...

Page 23: ...esh water module regulates the temperature at which the connected hot water devices receive water 8 Recirculation control optional additional function A recirculation line means that hot water can be...

Page 24: ...ulation temperature The control takes the recirculation temperature required recirculation temperature into account within the time release This means that the pump is only cycled if the recirculation...

Page 25: ...ffer cylinder operating mode may be adjusted by qualified per sonnel only 6 Buffer tank status line Set buffer tank temperatures Min buffer temp top When Buffer cylinder temperature top falls below th...

Page 26: ...l upon purchase DR 0007 i The solar yield is displayed in the mySOLARFOCUS app 27 prerequisite A solar system controlled by the controlecomanager touch including thermal unit counter 11 Temperature di...

Page 27: ...Create a connection between the router and the boiler control panel touch display Use the following socket RJ45 on the rear of the dis play for the boilers octoplus pellettop and pelletelegance Centra...

Page 28: ...he app Press the Register new user button Fig 2 42 Enter the information required and press the Regis ter button An email will be sent to the email address you provided Open the email and click on the...

Page 29: ...eating circuit screen in room settings in the heating curve screen Changes using the app In the heating circuit screen only Daily time swit ching is available in heating circuit mode and not In blocks...

Page 30: ...lowing see mySOLARFOCUS app 27 n Has your heating system been correctly registered on the SOLARFOCUS web server n Is the connection status between the control and the SOLARFOCUS web server online n Is...

Page 31: ...ture or the room temperature 100 maximum reduction in the heating circuit flow temperature or the room temperature in the event of good weather being forecast Within the heating period the heating cir...

Page 32: ...uisite for permanently reliable functioning of the boiler for energy saving and environmentally fri endly operation of the boiler for a long service life of the boiler Basic information on boiler main...

Page 33: ...rried out by qualified personnel with a reminder to perform a boiler clea ning i You can use the function E Mail Message 16 to be informed about an upcoming empty ing of the ash container see Alarm se...

Page 34: ...i The stainless steel combustion grate must lie completely flat and horizontally When inclined ignition problems are possible or this can lead to uneven wear of the stainless steel combustion grate If...

Page 35: ...7 Replace pellet suction turbine The suction turbine for conveying the pellets is a wea ring part Depending on the degree of soiling 1 of the suction turbine the service life of the suction motor car...

Page 36: ...measurement release Press the button The prerequisites for a measurement release are tested Fig 2 57 As soon as Measurement enable appears in the status bar the measurement can be started The chimney...

Page 37: ...ircuit x 3 Ignition not possible Check the container fill level sensor x 4 Extraction room may be empty x 5 Flue gas temperature too low x Flue gas sensor interruption x 7 Flue gas sensor shows wrong...

Page 38: ...placed 8 Feeder sensor disruption The temperature sensor of the pellet auger has been disrupted and must be replaced 9 Flue gas sensor short circuit The flue gas temperature sensor has a defect and mu...

Page 39: ...s a power failure The boiler is ope rationally ready again 26 Mains fuse defective Mains fuse F3 on the electrical power element of the boiler is defective and must be replaced 27 Triac fuse defective...

Page 40: ...ull if a total of only two probes is present then if only one probe is still marked as full 43 Suction probe switching unit error Communication between the boiler control and the electronic module of...

Page 41: ...xtended by one year and bil led accordingly We reserve the right to impose annual price adjustments and this should be taken into account The prices quoted are without the statutory value added tax Ru...

Page 42: ...armotors n 5 years full warranty on all electrical components on the boiler such as motors sensors control touch control unit or ignition n 5 years warranty on wear parts Wearing parts are charged fro...

Page 43: ...y class A A A A Nominal heat output Pr kW 35 44 9 49 70 Energy Efficiency Index EEI 121 122 122 122 Space heating annual usage s 82 83 83 83 Special precautions to be taken for assembly installation a...

Page 44: ...ustria Biomass heating Solar systems Heat pumps Fresh water equipment Innovative products to spare the environment and your wallet Tested state of the art technology EN ISO 9001 certified Austria make...