Fan
: Provides information about the fan status: OK, or Not working. For more information, refer to
External Fan Maintenance and Replacement
Multiple Inverters Status
The Multiple Inverters status screen shows the status of all inverters connected to a master inverter in a
chain (bus). The master inverter is displayed first, and the connected inverters (slaves) appear one after
the other when scrolling.
For inverters with secondary units, the status of secondary units is displayed on the screen. If a
secondary unit is not operating, its column is grayed-out.
Status
Multi-inverters
Production
1.00 MW
Limit
1.00 MW
Inverters
10/10
Inverter
SN 07318000C
Power
100 kW
Voltage
277 Vac
Frequency
60.9 Hz
P_OK: 141 0f 141
Optimizers Connected
S_OK
Server Connected
Status
Production
Switch
OFF
CosPhi
1.00
Limit
Export
Country
ITA
Inverter Units
Secondary 1
N/C
Voltage
N/A
P_OK
N/A
Temperature
N/A
Fan
N/A
Primary
SN 07318000C
Voltage
850 Vdc
P_OK
47 0f 47
Temperature
156 F
Fan
OK
Secondary 2
SN 07318000E
Voltage
850 Vdc
P_OK
47 0f 47
Temperature
156 F
Fan
OK
Switch Off. Production disabled
›
Commissioning
l
Site
status:
o
Production
: The AC output power
Three Phase Inverter with synergy technology Guide MAN-01-00402-1.1
50
Multiple Inverters Status