Troubleshooting the Meter using the
Device Display
The communication status screen should display the
following:
D e v P r o t # #
R S 4 8 5 - 1 < M T R > < S E > < 1 >
R S 4 8 5 - 2 < - - - > < - - > < - - >
Z i g B e e < - - - > < - - > < - - >
Device Type or Protocol are configured
incorrectly
If
MTR
(meter) is not displayed as the device type (DEV), or
SE
(SolarEdge) is not displayed as the Prot (protocol), configure
the meter as follows.:
1. Select
Communication
è
RS485-x Conf
è
Device Type
è
Revenue Meter
.
2. Select Communication
è
RS485-x Conf
è
Protocol
è
SolarEdge
.
3. Check that the meter's Modbus address specified in
Communication
è
RS485-x Conf
è
Device ID
corresponds to the meters' DIP switch settings. Refer to
Revenue Grade Energy Meter with Modbus Connection Installation Guide MAN-01-00609-1.0