SolarEdge PV 60MMJ Series Installation Manual Download Page 2

Disclaimers

1

Disclaimers

Important

 

Notice

Copyright

 

©

 

SolarEdge

 

Inc.

 

All

 

rights

 

reserved.

No

 

part

 

of

 

this

 

document

 

may

 

be

 

reproduced,

 

stored

 

in

 

a

 

retrieval

 

system

 

or

 

transmitted,

 

in

 

any

 

form

 

or

 

by

 

any

 

means,

 

electronic,

 

mechanical,

 

photographic,

 

magnetic

 

or

 

otherwise,

 

without

 

the

 

prior

 

written

 

permission

 

of

 

SolarEdge

 

Inc.

The

 

material

 

furnished

 

in

 

this

 

document

 

is

 

believed

 

to

 

be

 

accurate

 

and

 

reliable.

 

However,

 

SolarEdge

 

assumes

 

no

 

responsibility

 

for

 

the

 

use

 

of

 

this

 

material.

 

SolarEdge

 

reserves

 

the

 

right

 

to

 

make

 

changes

 

to

 

the

 

material

 

at

 

any

 

time

 

and

 

without

 

notice.

 

You

 

may

 

refer

 

to

 

the

 

SolarEdge

 

web

 

site

 

(

www.solaredge.com

)

 

for

 

the

 

most

 

updated

 

version.

All

 

company

 

and

 

brand

 

products

 

and

 

service

 

names

 

are

 

trademarks

 

or

 

registered

 

trademarks

 

of

 

their

 

respective

 

holders.

Patent

 

marking

 

notice:

 

see

 

http://www.solaredge.com/patent

The

 

general

 

terms

 

and

 

conditions

 

of

 

delivery

 

of

 

SolarEdge

 

shall

 

apply.

The

 

content

 

of

 

these

 

documents

 

is

 

continually

 

reviewed

 

and

 

amended,

 

where

 

necessary.

 

However,

 

discrepancies

 

cannot

 

be

 

excluded.

 

No

 

guarantee

 

is

 

made

 

for

 

the

 

completeness

 

of

 

these

 

documents.

Please

 

note:

 

This

 

product

 

is

 

intended

 

to

 

provide

 

remote

 

shutdown

 

of

 

the

 

SolarEdge

 

PV

 

harvesting

 

system,

 

to

 

enable

 

safer

 

access

 

to

 

a

 

building

 

in

 

the

 

event

 

of

 

fire.

 

This

 

product

 

DOES

 

NOT

 

reduce

 

the

 

risk

 

of

 

fire

 

or

 

protect

 

firefighters

 

or

 

others

 

accessing

 

a

 

building

 

in

 

the

 

event

 

of

 

a

 

fire.

The

 

images

 

contained

 

in

 

this

 

document

 

are

 

for

 

illustrative

 

purposes

 

only

 

and

 

may

 

vary

 

depending

 

on

 

product

 

models.

Emission

 

Compliance

This

 

equipment

 

has

 

been

 

tested

 

and

 

found

 

to

 

comply

 

with

 

the

 

limits

 

applied

 

by

 

the

 

local

 

regulations.

These

 

limits

 

are

 

designed

 

to

 

provide

 

reasonable

 

protection

 

against

 

harmful

 

interference

 

in

 

a

 

residential

 

installation.

 

This

 

equipment

 

generates,

 

uses

 

and

 

can

 

radiate

 

radio

 

frequency

 

energy

 

and,

 

if

 

not

 

installed

 

and

 

used

 

in

 

accordance

 

with

 

the

 

instructions,

 

may

 

cause

 

harmful

 

interference

 

to

 

radio

 

communications.

 

However,

 

there

 

is

 

no

 

guarantee

 

that

 

interference

 

will

 

not

 

occur

 

in

 

a

 

particular

 

installation.

 

If

 

this

 

equipment

 

does

 

cause

 

harmful

 

interference

 

to

 

radio

 

or

 

television

 

reception,

 

which

 

can

 

be

 

determined

 

by

 

turning

 

the

 

equipment

 

off

 

and

 

on,

 

you

 

are

 

encouraged

 

to

 

try

 

to

 

correct

 

the

 

interference

 

by

 

one

 

or

 

more

 

of

 

the

 

following

 

measures:

Smart

 

Modules

 

Installation

 

Guide

 

MAN-01-00520-1.3

Summary of Contents for PV 60MMJ Series

Page 1: ...Installation Guide Smart Modules Version 1 3...

Page 2: ...e completeness of these documents Please note This product is intended to provide remote shutdown of the SolarEdge PV harvesting system to enable safer access to a building in the event of fire This p...

Page 3: ...a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Changes or modifications not expressly approved by the party responsi...

Page 4: ...ance and Disposal 21 Support Contact Information 22 Version History Version 1 3 March 2020 Modified Chapter 3 Mechanical Installation Add Chapter 4 Reporting and Monitoring Installation Data Version 1...

Page 5: ...drop the PV module or drop objects onto the module Do not attempt to disassemble the modules and do not remove any attached components from the modules Do not scratch or otherwise harm the back sheet...

Page 6: ...f output connectors with bare hands Do not unplug the connectors under laod It is recommended not to work alone Wear a safety belt if working far above the ground Do not wear metallic jewelry which ca...

Page 7: ...Do not touch terminals connectors and modules while the system is on Do not stand walk drop or put objects on the module Damaged modules broken glass torn back sheet broken junction box broken connect...

Page 8: ...ion When installing the module installers must conform to all safety precautions detailed in this guide Limitation of Liability Because the use of this manual and the conditions or methods of installa...

Page 9: ...C The fire safety rating of this module is valid only when mounted in the manner specified in the mechanical mounting instructions Do not install modules at locations that come with direct contact of...

Page 10: ...the middle clamps are a 40 mm b 26 mm c 8 mm d 28 mm and 9 mm SeeFigure 2 The recommended torque for tightening the bolts and nuts is 28 N m when the bolts and nuts have property is Class 8 8 To fast...

Page 11: ...Figure 3 End clamp and middle clamp installation 6 For mounting the supporting rails on the long side of the frame slide bolts through the rail grooves next to the 4 clamp locations The module may be...

Page 12: ...on the long side of the frame 7 For mounting the supporting rails on the short side of the frame slide bolts through the rail grooves next to the 4 clamps locations The module may be clamped only in t...

Page 13: ...Type Series Dimension D E F Clamping Range SPVxxx 60MMJ 1650 992 40 mm 992 mm 50 mm 150 mm Table 3 Modules dimensions for mounting rails on the short side of the frame Smart Modules Installation Guid...

Page 14: ...clamp by attaching a plain washer spring washer and nut in that order Figure 7 Attaching mounting clamp Ensure the clamps overlap the module frame by at least 5 mm 0 2 in Ensure the clamps overlap len...

Page 15: ...washer and nut in that order Figure 8 Clamping the SPVxxx R60LWMG SPVxxx R60LBMG Modules 6 For mounting the supporting rails on the frame slide bolts through the rail grooves next to the four clamp l...

Page 16: ...60LBMG 1776 1052 40 mm 340 550 mm 410 490 mm Table 4 Mounting dimensions for rails on the Monocrystalline PERC module with half cut cell technology and integrated power optimizer Chapter 2 Mechanical...

Page 17: ...determining component voltage ratings conductor capacities over current device ratings and size of controls connected to the PV output Each series connected string of modules shall be provided with th...

Page 18: ...stainless steel See Figure 10 Secure the ground wire on fixed end through fastening bolt note that the copper wire cannot be attached directly to the aluminum Insert the bolt through the fixed end an...

Page 19: ...nverters strings modules meters and sensors as well as their electrical connectivity This view enables you to see which modules are connected in each string which strings are connected to each inverte...

Page 20: ...g platform and enables Simple on site registration of new systems Creating editing and verifying system physical layout Scanning and assigning the module and power optimizer serial numbers in the syst...

Page 21: ...s physical layouttemplate pdf using the detachable 2D barcode stickers on each power optimizer Once the form is completed use the Mapper to scan the 2D codes and create the map in the monitoring platf...

Page 22: ...le with clean non heated water and a gentle implement a sponge for example Never use chemicals on the surface of the module If there is snow use a soft bristled brush to clean the surface of the modul...

Page 23: ...mobile application LCD screen or on the monitoring platform or by the LEDs if there is such an indication System configuration information including the type and number of modules connected and the nu...

Page 24: ......

Reviews: