Appendix A: Mounting the ZigBee Plug-in in
the Firefighter Gateway
NOTE
The ZigBee Plug-in should be purchased separately.
1. Turn the inverter Safety Switch (if applicable) to OFF.
2. Turn the inverter ON/OFF switch to OFF.
3. Disconnect the AC to the inverter by turning OFF the circuit breakers on the
distribution panel. Wait 5 minutes for the capacitors to discharge.
4. Open the Firefighter Gateway cover.
5. Unscrew the nut and washer on the ZigBee Plug-in.
6. Connect the ZigBee Plug-in in a Firefighter Gateway board as shown below, and
ensure that:
the antenna connector at the end of the ZigBee Plug-in goes through the bracket.
all pins are correctly positioned in the Firefighter Gateway socket and no pins are
left out of their socket.
the card is firmly in place.
Figure 19: ZigBee Plug-in on a Firefighter Gateway board
3. Screw in the nut and washer on the ZigBee Plug-in
4. Connect the antenna.
5. Replace the Firefighter Gateway cover.
Appendix A: Mounting the ZigBee Plug-in in the Firefighter Gateway
48
Firefighter Gateway Installation Guide MAN-01-00113-1.4