1. Close the inverter cover: Attach the inverter cover and secure it by tightening the
screws with a torque of . For proper sealing, first tighten the corner screws and then
the two central screws.
2. If not already ON - Turn ON the AC to the inverter by turning ON the circuit breaker
on the main distribution panel and turning on the (if applicable).
3. Wait for the inverter to connect to the SolarEdge monitoring platform. This may take
up to two minutes.
A status screen similar to the following appears on the LCD panel:
V a c [ V ] V d c [ V ] P a c [ w ]
2 4 0 . 7 1 4 . 1 0 . 0
P _ O K : 0 0 0 / 0 0 0 < S _ O K >
- - - - - - - - - - - - - - -
O F F
S_OK: Indicates that the connection to the SolarEdge monitoring platform is successful.
If S_OK is not displayed, refer to
.
Additional Connection Options
Creating a Wireless ZigBee Connection
This communication option enables using a ZigBee connection to connect one or
several devices to the monitoring platform.
The ZigBee device is provided with a user manual, which should be
reviewed prior to connection. It is available on the SolarEdge website at
http://www.solaredge.com/groups/products/communication
Creating a Wi-Fi Connection
This communication option enables using a Wi-Fi connection for connecting the
device to the monitoring platform.
The Wi-Fi Plug-in kit can be purchased separately and assembled during
system installation. The Wi-Fi Plug-in kit is provided with a user manual,
which should be reviewed prior to connection. It is available on the
SolarEdge website at
http://www.solaredge.com/groups/products/communication
Chapter 3: Connecting the Firefighter Gateway to the Installation
28
Firefighter Gateway Installation Guide MAN-01-00113-1.4