Figure 7: 3-pin terminal block
2. Connect the 3-pin terminal block to the designated RS485-1 port on the Firefighter
Gateway.
NOTE
RS485-1 is configured as SolarEdge device by default, therefore RS485-
1 is used as the RS485 bus connection point.
3. If the Firefighter Gateway is at the end of the RS485 chain, terminate the Firefighter
Gateway by switching a termination DIP switch to ON. The switches in the SolarEdge
Firefighter Gateway are marked SW1 for the RS485-1 port termination (and SW2), as
shown below:
Figure 8: RS485 connectors and termination switches
4. Open the inverter cover as described in their manual.
5. Remove the seal from one of the openings in communication gland #2 of the
inverter and insert the cable through the opening.
6. Pull out the 9-pin RS485 terminal block connector, as shown below:
Firefighter Gateway Installation Guide MAN-01-00113-1.4
19
Creating an RS485 Bus Connection