475
Stiebel-Eltron
4
Stiebel-Eltron
4.1
Stiebel Eltron Heat pumps (ISG)
Termination
Addressing
Interface
No
Yes
LAN
Overview
•
Integrated interface.
•
The Stiebel-Eltron heat pump‘s IP address must be adapted.
•
Connected using network cable (patch cable) and Ethernet router or switch (when assigning a static IP ad-
dress).
•
Installation steps:
•
Assign heap pump a static IP address or via
DHCP (enabled by default).
•
Connect the heat pump to a switch (with a static IP address) or Ethernet router.
•
Connect the Solar-Log™ to a switch (with a static IP address) or Ethernet router.
Assigning IP addresses
•
Configure the address according to the manufacturer‘s manual.
•
The DHCP range (IP address) for the heat pump has to be in the same subnet as the Solar-Log™.
•
Procedure: According to the manufacturer‘s manual.
Detection via the Solar-Log™ WEB Interface
•
For detection on the Solar-Log™ , select the device class under the menu
Configuration | Device | Definition
| Interface
with the plus symbol and then select Stiebel-Eltron as the manufacturer. Confirm your selection
with
OK
.
•
Save your selections and then start the Device Detection under
Configuration | Device | Detection
.
•
After the detection, Stiebel-Eltron appears as a switching device in the
Configuration | Smart Energy | Swit-
ching Groups menu
.
•
Assign the switch contact of the Stiebel heat pump to a switching group (the switch contact only needs to be
defined in the software, no hardware is required) and configure the specific control for the heat pump. For
more information on Smart Energy such as configuration, functionality and application examples, refer to
Chapter 5.2: „Controlling Heat Pumps with a Grid Company Blocking Signal“
(
https://www.solar-log.com/manuals/manuals/en_GB/SolarLog_Manual_Smart_Energy_EN_01.pdf
).
•
The heat pump appears in the
Diagnostics | Smart Energy | Status (current)
and
history menu
(also with
several temperature values that are retrieved and recorded from the heat pump).
Detection from the Solar-Log 1200
•
When using the Solar-Log 1200, the detection can also be started from the display. Select the settings
►
Start
►
Initial Configuration
►
Page 2 „Device“
►
Add and select the manufacturer Stiebel-Eltron from there. Save
and start the Device Detection.
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...